3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A

Test voltage:
Voltage drop: 1V max@30A
Weight:
20 kg
Dimensions:
19" / 4 U
Output:
DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal output
Peak current:
60A duration time 500 ms
Pulse duration:
Drop duration time td 1us - 10 s
Repetition rate:
100 ms - 999s
Source Impedance:
High resistance or low resistance
Test Voltage:
0–60 V
Trigger:
External trigger signal by oscilloscope, BNC,5V TTL
Trigger of bursts:
Automatic, manual, external
Manufacturer:
3ctest
Online Orders Ship Same Day

 

SKU:
sku-588

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The 3ctest PFS 6030A Automotive Power Failure Simulator is a standalone test equipment with electronic switch inside, it can simulate voltage dip and drop (micro interruption) and ensure the voltage fast rising or falling time to be within 1µs.

It needs two DC voltage sources for simulating voltage dip, but needs only one DC voltage source for simulating voltage drop (micro interruption).

With the original technology of output impedance variable, it can simulate the power failure much more closely, simulating open circuit at high impedance and short circuit at low impedance, waveforms complying with standards under different resistive loads. PFS A series Automotive Power Failure Simulator can be operated manually or via Ethernet interface controlled by AutoLab software. EUT power supply voltage can be switched quickly under the program control. The switch has two input ports to connect two power supplies. The load bearing of DC switching is up to 60V, available for 42V power system test

Software (Optional)

PC control by AutoLab Support windowsXP and Windows7, easy to operate and nice-looking appearance Kinds of operating functions and standard library can be self-defined by users. It is available to identify the connected devices automatically/manually and configure automatically. Based on template report, users can generate test report flexibly

The EMC Shop offers on-site support for rentals and sales of power fail simulators.

Contact us for more information on the 3ctest PFS 6030A

Technical Parameters
Voltage at primary input terminal PF1 0 to 60 V
Current 30A
Switching time Less than 1us (rising/fall time); less than 10us for high resistance 1kΩ
Peak Current Two times of the rated current with duration 500ms
Output impedance High resistance or low resistance

Key Considerations

Manufacturer:
3ctest
Test voltage:
Voltage drop: 1V max@30A
Weight:
20 kg
Dimensions:
19" / 4 U
Output:
DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal output
Peak current:
60A duration time 500 ms
Pulse duration:
Drop duration time td 1us - 10 s
Repetition rate:
100 ms - 999s
Source Impedance:
High resistance or low resistance
Test Voltage:
0–60 V
Trigger:
External trigger signal by oscilloscope, BNC,5V TTL
Trigger of bursts:
Automatic, manual, external

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.