ETSI EN 301 489-1

(Showing 6 of 6)

ETSI EN 301 489-1 defines performance criteria for continuous phenomena applied to transmitters (CT) and receivers (CR), transient phenomena to transimetters (TT) and receivers (TR). The EMC Shop supports pre-compliant and fully compliant intentional radiated testing for ETSI EN 301 489-1, helping customers become competent in testing with the purchase of turn key test systems.

Get Application Support, Pricing, Lead Time and More: Contact Form

Test Methods Applied:

 

  • Teseq

    SKU: sku-221

    Teseq CDN 3083-Burst 1000 Volt, 100-200 Amp Coupler for EFT/Burst

    Weight: 11 kg (24 lbs)
    Application/Test Type: EFT/Burst testing of equipment requiring large currents, specially designed for heavy industry, smart grid and electro vehicle applications.
    Current Rating: 100 Amp or 200 Amp continous depending on model
    Dimensions: 430 x 310 x 190 mm
    Mains & EUT Connections: SHV; Screw terminals, rated for 200 A
    Standards Met: IEC / EN 61000-4-4 up to 8.8 kV
    Voltage Rating: 690 V AC RMS; 1000 VDC
  • Teseq

    SKU: sku-182

    Rent Teseq NSG 3060 for Surge, EFT/Burst, Dips/Interrupts, and Ring Wave up to 6.6 kV

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: ANSI / IEC / external
    Coupling-2: ANSI / IEC / external
    Dips, Interrupts & Variations: From EUT voltage input to 0 V, 0%
    Impedance: 12/30/200 Ω
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Phase synchronization-2: asynchronous, synchronous 0 to 359º (in 1º steps)
    Phase synchronization-3: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: positive / negative / alternate
    Polarity-2: positive / negative / alternate
    Pulse current (short circuit): ±16.6 to ±550 A, ±10%; ±6.6 to ±220 A, ±10%; ±1 to ±33 A, ±10%
    Pulse repetition: 10* s, up to 600 s (in 1 s steps) * see datasheet for derating info
    Pulse voltage (open circuit): ± 200 V to 6.6 kV (in 1 V steps)
    Repetition time: 40 μs to 35 min, 1 to 99’999 cycles
    Test duration: 1 s to 1000 h
    Test duration-2: 1 s to 70’000 min, 1 to 99’999 events, continuous
    Test duration-3: 1 to 9999 pulses, continuous
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 100 Hz to 1000 kHz
    Burst time: 1 μs to 1999 s, single pulse, continuous
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-3: ANSI / IEC / external
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Event time: 20 µs to 1999 s, 1 to 300 cycles or 1 to 3’000 1/10 cycles
    Impedance-2: 2/12 Ω
    Phase synchronization-4: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity-3: positive / negative / alternate
    Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit; ±100 V to 2.4 kV (50 Ω matching system)
    Pulse current (short circuit)-2: ±100 A to 3.3 kA
    Pulse repetition-2: 10* s, up to 600 s (in 1 s steps) * see datasheet for derating info
    Pulse voltage (open circuit)-2: ±200 V to 6.6 kV (in 1 V steps)
    Repetition time-2: 1 ms to 4200 s (70 min)
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Switching times: 1 to 5 μs (100 Ω load)
    Test duration-4: 1 to 9999 pulses, continuous
    Uvar with optional variac: depending on model (VAR 3005)
    Uvar with step transformer: 0, 40, 70, 80% (INA 650x)
    Typically In Stock
  • EM Test

    SKU: sku-645

    EM Test Dito ESD Simulator up to 16.5 kV for IEC/EN 61000-4-2

    Weight: 870 gramms incl. battery
    Additional Accessories: DM1 150pF/330ohm discharge module PowerPack dito Rechargeable battery LiFePo4 12.8V - 1000mAh Battery charger Transportation case, grounding lead 2m, test certificate and operation manual
    Air Discharge Voltage Range: 500V - 16,500V +/-5%
    Contact Discharge Voltage Range: 500V - 10,000V +/-5%
    Electrostatic Discharge: Pulse conforms to IEC 61000-4-2 edition 2
    General Data: Technical Details
    Holding Time: More than 5 seconds
    Operating Temperature: 5°C - 40°C
    Output level: see data sheet
    Outputs: CD mode EN/IEC 61000-4-2; 150pF/330ohm
    Resolution: 100V steps
    Rise Time: 0.8ns +/- 25%
    Standards Met: IEC/EN 61000-4-2, ISO 10605
    Supply Voltage: More than 70,000 pulses @ 16.5kV; automatic power-off after 10 minutes if not operated LiFePo4 12.8V - 1000mAh
    Trigger: Automatic + Manual
  • EM Test

    SKU: sku-482

    Rent EM Test Dito 16.5 kV ESD Simulator for IEC/EN 61000-4-2

    Weight: 870 gramms incl. battery
    Additional Accessories: DM1 150pF/330ohm discharge module PowerPack dito Rechargeable battery LiFePo4 12.8V - 1000mAh Battery charger Transportation case, grounding lead 2m, test certificate and operation manual
    Air Discharge Voltage Range: 500V - 16,500V +/-5%
    Contact Discharge Voltage Range: 500V - 10,000V +/-5%
    Electrostatic Discharge: Pulse conforms to IEC 61000-4-2 edition 2
    General Data: Technical Details
    Holding Time: More than 5 seconds
    Operating Temperature: 5°C - 40°C
    Output level: see data sheet
    Outputs: CD mode EN/IEC 61000-4-2; 150pF/330ohm
    Resolution: 100V steps
    Rise Time: 0.8ns +/- 25%
    Standards Met: IEC/EN 61000-4-2, ISO 10605
    Supply Voltage: More than 70,000 pulses @ 16.5kV; automatic power-off after 10 minutes if not operated LiFePo4 12.8V - 1000mAh
    Trigger: Automatic + Manual