EN/IEC 61000-4-29

(Showing 5 of 5)

EMC testing equipment to certify and comply to EN/IEC 61000-4-29: DC Drops, Dips & Interruptions Immunity Testing. The EMC shop is the only online store for electromagnetic compliance test equipment.

  • SKU: sku-2151

    PQF-11/29 Voltage Interruption Simulator for IEC/EN 61000-4-11 and 4-29

    Weight: 13 Kg
    Communication: BNC outputs (on rear) for voltage, current and scope triggering
    Coupling: BNC
    Dimensions: 19″ housing, 3 HE
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    General Data: Technical Details
    Input: 230V / 50 Hz, 80VA
    Mains & EUT Connections: 4mm banana line
    Output Current: AC max. 280 V, DC max. 3 6 0 V
    Peak inrush current capability: 16 Amps
    Phase synchronization: at any phase position 0° - 360 °
    Repetition time: Asynchronous 5,0ms -9990ms Synchronous 20ms - 9980ms
    Supply Voltage: 230V / 50 Hz, 80VA,
    Test duration: 0.1sec - 9990sec, furthermore single event and continuous operation
    Test Voltage: AC max. 280 V ,DC max. 3 6 0 V
    Trigger: BNC
  • Schloder

    SKU: sku-784

    Schloder VIS 1700 Voltage Interruption Simulator

    Weight: 13 Kg
    Communication: BNC outputs (on rear) for voltage, current and scope triggering
    Coupling: BNC
    Dimensions: 19″ housing, 3 HE
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    General Data: Technical Details
    Input: 230V / 50 Hz, 80VA
    Mains & EUT Connections: 4mm banana line
    Output Current: AC max. 280 V, DC max. 3 6 0 V
    Peak inrush current capability: 16 Amps
    Phase synchronization: at any phase position 0° - 360 °
    Repetition time: Asynchronous 5,0ms -9990ms Synchronous 20ms - 9980ms
    Supply Voltage: 230V / 50 Hz, 80VA,
    Test duration: 0.1sec - 9990sec, furthermore single event and continuous operation
    Test Voltage: AC max. 280 V ,DC max. 3 6 0 V
    Trigger: BNC
  • 3ctest

    SKU: sku-591

    3ctest PFS 2216SVD Single Phase Power Fail Simulator w/ Two Semiconductor Switches for High Current Protection

    Weight: 40Kg
    Communication: Ethernet LAN、RJ45
    Coupling: BNC
    Dimensions: 19 inch/6U
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 45-65Hz
    General Data: Technical Details
    Input: BNC,5V TTL
    Mains & EUT Connections: 4mm banana line
    Maximum Continuous Power: 100W
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Phase synchronization: 0°- 360°,1° step or random
    Repetition time: 0.3-9999 cycle or 5ms-9999ms
    Rise time: 1-5us(100Ω load)
    Supply Voltage: 110V/220V, ±10%, 50/60Hz
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
  • 3ctest

    SKU: sku-590

    3ctest PFS 2216SD Single Phase Power Fail Simulator for EN/IEC 61000-4-11

    Weight: 40Kg
    Communication: Ethernet LAN、RJ45
    Coupling: BNC
    Dimensions: 19 inch/6U
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 45-65Hz
    General Data: Technical Details
    Input: BNC,5V TTL
    Mains & EUT Connections: 4mm banana line
    Maximum Continuous Power: 100W
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Phase synchronization: 0°- 360°,1° step or random
    Repetition time: 0.3-9999 cycle or 5ms-9999ms
    Rise time: 1-5us(100Ω load)
    Supply Voltage: 110V/220V, ±10%, 50/60Hz
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
  • Haefely

    SKU: sku-320

    Haefely ECOMPACT4 Precompliant EMC Impulse Generator

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4
    Applications: EMC Precompliance Testing, CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 230 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 60 Volts
    Max EUT DC Current (w/ Built in CDN): 16 Amps
    Peak inrush current capability: >500 Amps
    EFT/Burst Pulse Output Capability: 4.2 kV
    Combination/Wave Surge Output Capability: 4.2kV
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Dips, Interrupts & Variations: 0%, 40%, 70%, 80%
    Typically In Stock

Connect with The EMC Shop