EM Test Transient Generators

(Showing 12 of 37)

The EM TEST transient generators are the ideal starting point to set up an EMC test facility. Most versatile to meet many requirements but also most ecomomic in terms of cost they are designed for fully compliant conducted immunity testing. The following "all-in-one" solutions are available to meet your test requirements. The EMC Shop stocks an assortment of the EM Test transient generators and with online ordering it makes everything fast and easy.

EM Test Transient Generators

  • Surge: Generators for combination/wave test IEC 61000-4-5ANSI C63 and more.
  • EFT/Burst: Electrical Fast Transient Generators for IEC 61000-4-4.
  • Dips, Drops (& Variations): PQF/Powerline Tests in accordance to IEC 61000-4-114-29 and more.
  • Automotive: Assortment of transient surges found in DC powered vehicles..
  • Ring Wave: Oscillatory wave tests per IEC 61000-4-12, 4-18, ANSI and more.
  • Telecom: Additional tests on data lines in unison with surge simulation tests.
  • Flicker & Harmonics: Power sources and analyzer turn key systems per IEC 61000-3-2 and 3-3.
  • ESD: Electrostatic discharge immunity simulators per IEC 61000-4-2
  • Magnetic: Radiated magnetic susceptibility per IEC 61000-4-8 and IEC 61000-4-9


Software for EM Test

Control Software for EM Test Transient Generators

IEC.Control allows for remote operation, custom test sequences, an expansive test standards library and reporting.

EM Test Transient Generators Videos

 



Show 12 24 36
  • EM Test

    SKU: sku-2169

    EM Test Surge, EFT, PQF, Ring Wave Immunity System for 3 Phase, 100 Amp EUT

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts, Ring Wave
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 480 Volts
    Max EUT AC Current (w/ Built in CDN): 100 Amps (Per Phase)
    Max EUT DC Voltage (w/ Built in CDN): 1000 Volts
    Max EUT DC Current (w/ Built in CDN): 100 Amps
    Peak inrush current capability: 500 Amps
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 6.6 kV
    External Coupling: Data Lines (EFT & Surge)
    Dips & Interrupts: 40%, 70%, 80%; Interrupts - 0% (short and open)
    Ring Wave: 100 kHz, 6 kV
    RENTAL ONLY
  • EM Test

    SKU: sku-1292

    EM Test PFS 500 Power Fail Simulator for EN/IEC 61000-4-11

    Weight: app. 28kg;
    Current Rating: Max. 16 Amps
    Dimensions: 19"/6 HU
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Peak current: 500 Amps inrush
    Phase synchronization: phase angle 0° - 360° (1 Degree Resolution)
    Repetition rate: 0 - 99s, 16-500 Hz
    Supply Voltage: 115V/230V; +10/-15%
  • EM Test

    SKU: sku-1195

    Complete IEC/EN Test Rack for CE Marking and Conducted Immunity Certification

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
  • EM Test

    SKU: sku-921

    Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max
  • EM Test

    SKU: sku-817

    EM Test LD 200N Load Dump Generator for ISO 16750-2

    Output: +/- output Safety laboratory connectors Coupling To the battery +lineDecoupling Via diodeDUT supply Max. 80V/30A
    Freestyle Mode Micropulses: Rise time 1us 10us - 90us with 10us steps 100us - 900us with 100us steps 1ms - 10ms with 1ms steps Pulse duration 10ms - 1,200ms Int. resistor 0.5ohm - 38ohm, in steps of 0.1ohm
    Test Standards: ISO 7637-2 Pulse 5b for 12V and 24V, ISO/WD 16750 Pulse 5b, and much more
    Test Routines: Quick Start, User Defines Routines, Standards Test Routines Service
    $1,690.00 - $2,290.00
    Typically In Stock
  • EM Test

    SKU: sku-776

    Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68

    Weight: approx. 35kg
    Application/Test Type: Test levels as per FCC part 68
    Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PE
    Dimensions: 19“ / 6HU,
    Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)
    Outputs: 4 mm banana socket
    Polarity: pos / neg / alternate
    Rise time: Less than 2 us
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)
    Trigger of bursts: Automatic pulse release
  • EM Test

    SKU: sku-549

    EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32A

    Weight: app. 28kg;
    Current Rating: Max. 32A
    Dimensions: 19"/6 HU
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 50Hz/60Hz, Single phase application
    Output: 3-phase application L1, L2, L3, N and PE on the rear panel. 1-phase application L, N and PE on the front panel
    Peak current: Better than 500A
    Repetition rate: 0.01s to 9,999s
    Rise time: Between 1us and 5us for abrupt changes, generator loaded with resistive load
    Supply Voltage: 115V/230V; +10/-15%
    Test Voltage: 3x480V AC resp. 3x690V AC (L-L) 277V AC resp. 400V AC 360V DC resp. 600V DC (L-N)
    Trigger of bursts: Automatic
  • EM Test

    SKU: sku-547

    EM Test NX5 Compact EMC Generator for EFT/Burst, Surge & Power Fail up to 5.5 kV

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Max EUT Voltage (w/ Built in CDN): 300 Volts
    Max EUT Current (w/ Built in CDN): 16 Amps
    Peak inrush current capability: 500 Amps (up to 2.5 kA)
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 5 kV
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Dips, Interrupts & Variations: 16 Hz - 500 Hz and DC
    INQUIRE