Combination Wave/Surge Generators

(Showing 12 of 14)

The EMC Shop stocks combination wave surge generators for conducted immunity testing and compliance according to IEC 61000-4-5. UL 1449, ANSI C62.41 and more.

 

See - Surge Immunity Test, Setup, Equipment

Conducted
Immunity & Susceptibility

Parameters Specifications
Standard

IEC 61000-4-5:2017 and IEC 61000-4-5:2005

Coupling waveform
1.2/50us, 10/700us
Coupled current waveform
8/20us, 5/320us
Pulse voltage
6kV (10 kV, customized)
Coupling mode
Common mode, line to ground
Coupling device
90V gas discharging tube
Output impedance
Current-limiting resistance can be replaced according to test requirements
Communication port
RJ45 female connector to connect telecommunication cable
Pin layout
Pair 1: pins 1 / 2 Pair 2: pins 3 / 6 Pair 3: pins 4 /5 Pair 4: pins 7 / 8
Data rate
10MBit/s, 100MBit/s, 1,000MBit/s
Working voltage
DC:3-12V
Working current
Max. 1A
Residual voltage
<15% of coupling surge voltage

Show 12
  • The EMC Shop

    SKU: sku-1857

    Surge4-5 Combination Wave Surge Generator per EN/IEC 61000-4-5

    Applications: EMC Surge, CE Marking
    Max EUT AC Voltage (W/ Built In CDN): 230 Volts
    Max EUT AC Current (W/ Built In CDN): 16 Amps
    Max EUT DC Voltage (W/ Built In CDN): 270 Volts
    Max EUT DC Current (W/ Built In CDN): 16 Amps
    Combination/Wave Surge Output Capability: 4.4 kV
    External Coupling: Data Lines (Surge), 3PH EUT
    Calibration: ISO 17025 Accredited (Upon Request)
    Videos: Manual
    Usually ships in 24 hours.
  • 3ctest

    SKU: sku-331

    3ctest CWS 600 6kV Surge Simulator for IEC 61000-4-5

    Weight: Approx 30 kg (66 lbs)
    Standards Met: UL1449, IEC/EN 61000-4-5, IEC/ISO 60601-1-2
    Coupling: Single Phase Built in, 16A, 250VAC, 120VDC
    Applications: EMC Surge, CE Marking
    Mains & EUT Connections: 4mm banana plug
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 0.1kA-3kA ±10%
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.2kV - 6kV ±10%
    Voltage Rating: AC 110V/220V , ±10%,
    $1,475.00
    $1,327.50
    In stock
  • EM Test

    SKU: sku-1287

    EM Test VCS 500 M10 10kV Combination Wave Surge Immunity Generator

    Weight: approx. 35kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Dimensions: 19"/6HU;
    Mains & EUT Connections: External Coupler Only
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: pos / neg / alternate
    Pulse current (short circuit): max. 5,000A ± 10%
    Pulse repetition: 1s - 999s, depending on the voltage
    Pulse voltage (open circuit): 500V - 10,000V ± 10%
    Supply Voltage: 115/230V +10/-15%
    Test duration: 1 - 30,000 or endless
  • Haefely

    SKU: sku-574

    Haefely PSURGE 4010 Surge Generator for IEC 61000-4-5 Testing

    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5
    Polarity: positive, negative, alternating
    Pulse current (short circuit): 100 Amps to 2.1 kA
    Pulse repetition: up to 12 per minute
    Pulse voltage (open circuit): 200 Volts to 4.2 kV
    Standards Met: EN/IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2 (IEC 61000-4-9 w/ MSURGE)
  • 3ctest

    SKU: sku-326

    3ctest SG 5010H 10kV Surge Simulator for IEC 61000-4-5, GB/T, ITU-T K21/K44

    Polarity: +/-, positive first or negative first
    Weight: Approximately 300 kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 1 or 3 Phase 16 Amps 250V/450V
    Impedance: 500Ω±10%
    Input voltage UIN: AC220V±10%,50/60H
    Output Current: 10/700 and 5/320±20%μs
    Polarity-2: +/-, positive first or alternate
    Pulse current (short circuit): 150A - 3kA/5kA (±10%)
    Pulse voltage (open circuit): 300V - 6kV/10kV (±10%)
    Standards Met: EN/IEC 61000-4-5, IEC 61643-1, GB/T 17626.5m GB/T 16927.1, ITU-T K21 and ITU-T K44
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: Voltage - 50μs(±20%); Current - 20μs(±20%)
    Test Voltage: 300V~6Kv/10kV (±10%)
    Transfer Impedance: 15Ω、40Ω(25+15Ω
  • Haefely

    SKU: sku-297

    Rent Haefely PIM 100 Combination Wave Impulse Module for IEC 61000-4-5 and ANSI C62.41

    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 3 Phase - 32 Amps, 690 VAC
    Dimensions: 45 x 20 x 57 cm
    Impedance: 2 Ohms
    Phase synchronization: 1° steps
    Polarity: pos / neg
    Pulse current (short circuit): 0.1 – 3.7 kA ±10% (8 us ±20% risetime)
    Pulse repetition: 10 seconds / 6 per minute
    Pulse voltage (open circuit): 0.2 – 7.4kV ±10% (1.2 us ±30% risetime)
    Standards Met: IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45
    Test duration: 50 us ±20% (Voltage) ; 20 us ±20% (Current)
  • Haefely

    SKU: sku-280

    Rent Haefely PSURGE 4010 Surge Generator for IEC 61000-4-5 Testing

    Test Standards: EN/IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2 (IEC 61000-4-9 w/ MSURGE)
    Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5
    Pulse current (short circuit): 100 Amps to 2.1 kA
    Pulse repetition: up to 12 per minute
    Pulse voltage (open circuit): 200 Volts to 4.2 kV

Connect with The EMC Shop