Surge Simulation (Power & Telecom Lines)

(Showing 12 of 20)

IEC 61000-4-5 is the most commonly referenced international standard to meet eelctrical surge/combo wave test requirements for power and telecom lines. Specialized surge simulators are available to meet specialized industrial and aerospace applications.

Show 12
  • Noiseken

    SKU: sku-800

    Noiseken LSS-15AX Series Lightning Surge Simulator up to 15kV

    Weight: 200 kg.
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: AC/DC lines CDN, and Telecom lines CDN
    Dimensions: 555 X 1250 X 790 mm
    Impedance: 2 Ohm
    Mains & EUT Connections: 4mm banana plug
    Phase synchronization: 0°-360°, 1°step or random
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 15kV/7500A
    Pulse repetition: 20 sec
    Pulse voltage (open circuit): 15kV/7500A
    Standards Met: IEC 61000-4-5
  • Schloder

    SKU: sku-783

    Schloder CWG 1500 Surge Generator, 4.4 kV, 2.2 kA, EN/IEC 61000-4-5

    Condition (5-10 Scale): 9
    Warranty: 6 Months
    Calibration: Fresh w/ Data at Time of Order
    Test standard: IEC 61000-4-5
    Accessorries: Complete
    Input: 120VAC/1PH
    Phase synchronization: 0 - 359°, step 1° net sync. triggering
    Polarity: pos / neg / alternate
    Pulse current (short circuit): 0.1 - 2.2 kA
    Pulse voltage (open circuit): 0.2 - 4.4 kV
    Test duration: 10 - 990 sec
    $7,950.00
    1 LEFT
  • EM Test

    SKU: sku-747

    EM Test CSS 500N10 Current Surge Generator, 8/20us Up To 10ka

    Weight: approx. 66 lbs.
    Coupling: N/A
    Dimensions: 19"/6HU,
    Polarity: positive / negative / alternate
    Pulse current (short circuit): 0.4kA to 10kA +/-10%
    Pulse voltage (open circuit): 250V to 6,000V +/-10%, Step width 50V
    Repetition time: Max. 10 pulses per minute, depending on the charging voltage
  • Thermo Keytek

    SKU: sku-583

    Keytek (Thermo Fisher) CE Master for EFT, Surge, PQF

    Dips, Interrupts & Variations: 70%, 40%
    Polarity: positive / negative / alternate
    Weight: 29kg (64 lbs)
    Air Discharge Voltage Range: 500V - 8.8kV
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 1-100kHz
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Contact Discharge Voltage Range: 500V - 4.4kV
    Coupling: external
    Dimensions: Height 17.8cm (7.0in) Width 47cm (18.5in) Depth 56cm (22in)
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Electrostatic Discharge: Pulse conforms to IEC 61000-4-2 edition 2
    Magnetic Field Strength: 0.5A/m - 4A/m (IEC 1000-4-8)
    Outputs: Single Shot, 1 pulse/sec and 20 pulses/sec
    Polarity-2: positive / negative / alternate
    Pulse amplitude: more than 250Amps @ 120V, more than 500Amps @ 240V
    Pulse current (short circuit): 125A - 1.25kA
    Pulse voltage (open circuit): 250V - 2.5kV
    Supply Voltage: Input Voltage 90 - 250VAC
    Test duration: 1µs - 5µs
    Uvar with step transformer: 70%, 40%
  • Teseq

    SKU: sku-346

    Teseq CDN 118-T4 Coupling Decoupling Network set for 1.2/50 µs and 10/700 µs Surge Pulses on 1 or 2 twisted pairs

    Weight: 19.5 kg (43 lbs)
    Application/Test Type: 1.2/50 μs (2 ohms) and 10/700 μs (15 ohms) pulse up to 6.6 kV line to ground, 3 kV line to line (Pulse frequency: 3 per minute)
    Current Rating: 0.5 Amps
    Decoupling chokes 1 kHz: 20 mH nominal
    Dimensions: 335 x 232 x 180mm
    Mains & EUT Connections: 4 mm safety banana; Fischer 103
    Ohmic resistance per path: 3 Ω
    Series resistor: in relation to the selected pulse coupling network
    Transmission 3 dB BW: 250 kHz
    Voltage Rating: 250 Volts AC/DC
  • 3ctest

    SKU: sku-327

    3ctest CCS 600 Conducted Immunity Test System (Surge, EFT)

    Test Standards: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEC/EN 61000-4-29
    Max EUT AC Voltage (w/ Built in CDN): 250 Volts
    Max EUT AC Current (w/ Built in CDN): 20 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 16 Amps
    EFT/Burst Pulse Output Capability: 4.8 kV
    Combination/Wave Surge Output Capability: 6 kV
    Dips & Interrupts: 0% - 100%
    Typically In Stock
  • EM Test

    SKU: sku-241

    EM Test UCS500N7 Multifunctional Transient Immunity Simulator

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: L, N, PE; all combinations
    Coupling-2: L, N, PE; line to line and line(s) to ground
    Dips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2
    Impedance: 12 ohm and 30 ohm
    Phase synchronization: 0° - 360°, resolution 1° (16 - 500Hz)
    Phase synchronization-2: 0° - 360°, resolution 1° (16 - 500Hz)
    Phase synchronization-3: 0° - 360°, resolution 1°
    Polarity: positive / negative
    Polarity-2: Positive, negative
    Polarity-3: Positive, negative, alternating
    Pulse current (short circuit): Wave Shape
    Pulse repetition: Automatic, manual, external
    Pulse voltage (open circuit): 250 V - 6,000 V ± 10%
    Repetition time: 10ms - 9,999s
    Test duration: 0:01min - 99:59min
    Test duration-2: max. 1 Hz (1 s - 999 s)
    Weight: 25 kg's (55 Lbs)
    Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity tests
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 0.1 kHz - 1,000 kHz
    Burst time: 0.10ms - 999ms
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1 - 30,000 or endless, selectable
    Coupling-3: As per IEC 61000-4-5: Line to line with 2 ohm, Line(s) to ground with 12 ohm; As per ANSI/IEEE C62.41: Line to line with 2ohm, Line(s) to ground with 2ohm
    Dimensions: 19", 3HU
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Energy Storage Capacitor: 20 uF
    Event time: 20us - 9,999s
    Event Trigger: Automatic, manual, external
    Front Time: As per ITU and ETSI recommendations: 10 us ± 30%; As per FCC part 68, Pulse B: 9 us ± 30%; As per IEC 61000-4-5: 5 us ± 30%
    Impedance-2: 2 Ohm / 12 Ohm
    Output Current: 6 A - 175 A (short circuit) at 25 Ohm Output
    Outputs: For 2-wire T1/T2 with 25 ohm each & For 4-wire T1/T2/T3/T4 with 25 ohm each
    Peak inrush current capability: 500 Amps
    Phase synchronization-4: 0° - 360°, resolution 1°
    Polarity-4: positive / negative / alternating
    Pulse amplitude: 200V - 5,500V ± 10%; 100V - 2,750V ± 10% into 50ohm
    Pulse current (short circuit)-2: Max. 3,500 A ± 10%
    Pulse Duration: As per ITU and ETSI recommendations: 700 us ± 20%; As per FCC part 68, Pulse B: 720 us ± 20%; As per IEC 61000-4-5: 320 us ± 20%
    Pulse repetition-2: max. 0.5Hz (2s - 999s)
    Pulse voltage (open circuit)-2: 250 V - 7,000 V ± 10%
    Repetition Rate: Max. 0.33 Hz (3 s - 999 s)
    Repetition time-2: 10ms - 9,999ms
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Standards Met: ANSI/IEEE C62.41; IEC 61000-4-11; IEC 61000-4-12; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; EN 61000-6-1; EN 61000-6-2; ITU-T K.XX; UL 1741
    Switching times: Under 5us into a 100ohm resistive load
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration-3: 1 - 30,000 or endless, selectable
    Test Voltage: 250 V - 7,000 V ± 10%
    Uvar with optional variac: N/A
    Uvar with step transformer: 300V AC
  • EM Test

    SKU: sku-240

    EM Test UCS 500N5 Multifunctional Generator for EFT/Burst, Surge & Power Fail up to 5.5kV

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: L, N, PE; all combinations
    Dips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2
    Phase synchronization: 0° - 360°, resolution 1° (16 - 500Hz)
    Phase synchronization-2: 0° - 360°, resolution 1° (16 - 500Hz)
    Polarity: positive / negative
    Repetition time: 10ms - 9,999s
    Test duration: 0:01min - 99:59min
    Weight: 25 kg's (55 Lbs)
    Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity tests
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 0.1 kHz - 1,000 kHz
    Burst time: 0.10ms - 999ms
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-2: Line to line; Line(s) to ground
    Dimensions: 19", 3HU
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Event time: 20us - 9,999s
    Impedance: 2 Ohm
    Peak inrush current capability: 500 Amps
    Phase synchronization-3: 0° - 360°, resolution 1°
    Polarity-2: positive / negative / alternating
    Pulse amplitude: 200V - 5,500V ± 10%; 100V - 2,750V ± 10% into 50ohm
    Pulse current (short circuit): Max. 2,500A ± 10%
    Pulse repetition: max. 1Hz (1s - 999s)
    Pulse voltage (open circuit): 160V - 5,000V ± 10%
    Repetition time-2: 10ms - 9,999ms
    Standards Met: FCC 97-270 (part 68); IEC 60255-22-5; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; IEC 61326; IEC 61850-3
    Switching times: Under 5us into a 100ohm resistive load
    Test duration-2: 1 - 30,000 or endless, selectable
    Uvar with optional variac: N/A
    Uvar with step transformer: 300V AC + DC
  • The EMC Shop

    SKU: sku-1857

    Surge4-5 Combination Wave Surge Generator per EN/IEC 61000-4-5

    Applications: EMC Surge, CE Marking
    Max EUT AC Voltage (W/ Built In CDN): 230 Volts
    Max EUT AC Current (W/ Built In CDN): 16 Amps
    Max EUT DC Voltage (W/ Built In CDN): 270 Volts
    Max EUT DC Current (W/ Built In CDN): 16 Amps
    Combination/Wave Surge Output Capability: 4.4 kV
    External Coupling: Data Lines (Surge), 3PH EUT
    Calibration: ISO 17025 Accredited (Upon Request)
    Videos: Manual
    Usually ships in 24 hours.
  • Thermo Keytek

    SKU: sku-799

    Thermo Keytek E510A 10kV Surge Generator

    Coupling: Model E4551 - Single Phase 16 Amps
    Test duration: 1.0ms to 20ms; 1.0ms resolution or 1 to 200 pulses
    Coupling-2: 1 PH / 15 (16) Amps
    Phase synchronization: ±15° with optional coupler/decoupler
    Pulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%
    Pulse repetition: 1 shot/18 seconds
    Pulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt steps
    Repetition time: Adjustable from 300ms to 5s; 1ms resolution
    Typically In Stock
  • EM Test

    SKU: sku-796

    EM Test VCS 500N10 Combination Wave Simulator for IEC/EN 61000-4-5 up to 10kV/5kA

    Weight: approx. 35kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: IEC/external
    Dimensions: 19"/6HU;
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: pos / neg / alternate
    Pulse current (short circuit): max. 5,000A ± 10%
    Pulse repetition: 6s - 999s, depending on the voltage
    Pulse voltage (open circuit): 500V - 10,000V ± 10%
    Supply Voltage: 115/230V +10/-15%
    Test duration: 1 - 30,000 or endless

Connect with The EMC Shop