EN/IEC 61000-4-11

(Showing 8 of 8)

Waveforms can be programmed to meet the requirmenets of IEC 61000-4-11 using a standard AC power source. However, specific voltage dip generators can be used to save time and money, with the preprogrammed dips, interruptions and variations available for easy plug and play.  The EMC Shop stocks calibrated test equipment for voltage dips and interruptions as well as other conducted immunity testing. Rent, buy or lease AC voltage dip and interruptions generators per EN/IEC 61000-4-11 today.

Get Application Support, Pricing, Lead Time and More: Contact Form

IEC 61000-4-11 Generator Software

Test Software for Voltage Dips Generators

AC Short Interruption

Voltage Short Interruptions per IEC 61000-4-11

AC Voltage Dip

Voltage Dip Waveform IEC 61000-4-11

AC Voltage Variation

Voltage Variation Waveform per EN/IEC 61000-4-11

Video: IEC 61000-4-11 Voltage Dip Simulation

  • SKU: sku-2151

    PQF-11/29 Voltage Interruption Simulator for IEC/EN 61000-4-11 and 4-29

    Weight: 13 Kg
    Communication: BNC outputs (on rear) for voltage, current and scope triggering
    Coupling: BNC
    Dimensions: 19″ housing, 3 HE
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    General Data: Technical Details
    Input: 230V / 50 Hz, 80VA
    Mains & EUT Connections: 4mm banana line
    Output Current: AC max. 280 V, DC max. 3 6 0 V
    Peak inrush current capability: 16 Amps
    Phase synchronization: at any phase position 0° - 360 °
    Repetition time: Asynchronous 5,0ms -9990ms Synchronous 20ms - 9980ms
    Supply Voltage: 230V / 50 Hz, 80VA,
    Test duration: 0.1sec - 9990sec, furthermore single event and continuous operation
    Test Voltage: AC max. 280 V ,DC max. 3 6 0 V
    Trigger: BNC
  • EM Test

    SKU: sku-1292

    EM Test PFS 500 Power Fail Simulator for EN/IEC 61000-4-11

    Weight: app. 28kg;
    Current Rating: Max. 16 Amps
    Dimensions: 19"/6 HU
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Peak current: 500 Amps inrush
    Phase synchronization: phase angle 0° - 360° (1 Degree Resolution)
    Repetition rate: 0 - 99s, 16-500 Hz
    Supply Voltage: 115V/230V; +10/-15%
  • Schloder

    SKU: sku-788

    Schloder VIS 740 Step Transformer for Voltage Drops, IEC/EN 61000-4-11

    Weight: 27 kg
    Dimensions: 255 x 355 x 310 mm
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    General Data: Technical Details
    Input: Input voltage: 230 Volt, 50 Hz Input current: 16 A
    Mains & EUT Connections: Included Connector
    Output Current: 40 A until 5 second at 40 % 23 A until 5 second at 70 % 20 A until 5 second at 80 %
    Peak inrush current capability: 16 Amps
    Supply Voltage: 230 Volt, 50 Hz
  • 3ctest

    SKU: sku-590

    3ctest PFS 2216SD Single Phase Power Fail Simulator for EN/IEC 61000-4-11

    Weight: 40Kg
    Communication: Ethernet LAN、RJ45
    Coupling: BNC
    Dimensions: 19 inch/6U
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 45-65Hz
    General Data: Technical Details
    Input: BNC,5V TTL
    Mains & EUT Connections: 4mm banana line
    Maximum Continuous Power: 100W
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Phase synchronization: 0°- 360°,1° step or random
    Repetition time: 0.3-9999 cycle or 5ms-9999ms
    Rise time: 1-5us(100Ω load)
    Supply Voltage: 110V/220V, ±10%, 50/60Hz
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
  • Haefely

    SKU: sku-503

    Haefely PLINE 1610 Voltage Dips, Interruptions & Variations Simulator

    Weight: 49kg
    Coupling: BNC
    Dimensions: 45 x 28 x 50 cm
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 48 to 62 Hz
    General Data: Technical Details
    Output: U nom up to 16A rms continuous. 80% up to 20A rms for 5s.70% up to 23A rms for 5s.40% up to 40A rms for 5s
    Peak inrush current capability: more than 500A at 230V more than 250A at 115V
    Phase synchronization: Synchronous 0 to 360 resolution, Asynchronous
    Repetition time: Dips/Interrupt duration 30us to 70 min, Dips/Interrupt repet. rate 3ms to 11 hours
    Test duration: 1s to 100 hours
    Test Voltage: 0 to 264V
    Trigger: Auto, Manual, External
    $1,275.00
    Typically In Stock

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.