Com-Power LI-400C 10 kHz - 10 MHz LISN for Mil-STD 461
SKU: 7281
EUT Current Handling: 25 AmpEUT Voltage Handling:: 270 VAC ( Line to Ground ), 380 VDCApplications: Conducted Emissions, Automotive EV EMCTest Standards: CISPR 25, MIL-STD-461, ISO 7637Inductors: 50 μH ( air-core )Frequency Range: 10 kHz to 10 MHzConnector: N-type (f), SUPERCON® shrouded socketIn Stock -
Com-Power LI-3P-2100 9kHz - 30MHz Three Phase LISN for CISPR / ANSI
SKU: sku-895
Frequency Range: 9 kHz – 30 MHzInductors: 50Ω, 50/250 μH +5Ω, (4) Conductor NetworkMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2 -
Com-Power LI-3P-263 9kHz – 30MHz Three Phase LISN for CISPR / ANSI
SKU: 11894
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent rating: 63 AmperesDimensions: 19.3” x 13.9” x 2.3″Frequency Range: 9 kHz – 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Typically In Stock -
Com-Power LI-3P-232 Three Phase LISN for CISPR / ANSI
SKU: sku-893
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent rating: 32 AmperesDimensions: 19.3” x 13.9” x 2.3″Frequency Range: 9 kHz – 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2 -
Com-Power LI-150C Line Impedance Stabilization Network
SKU: sku-890
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 50 Amps (AC), 35 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 5 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LIN-120C Line Impedance Stabilization Network
SKU: sku-889
Weight: 10 lbs (4.5 kg)Application/Test Type: Power line conducted emissions testsCurrent Rating: 20 Amps AC (rms) , 14 Amps DCDimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)Frequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUTRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2, ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LI-125C 150 kHz to 30 MHz Line Impedance Stabilization Network Pair
SKU: sku-881
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 25 Amps (AC), 17 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LI-3P-1100 150 kHz - 30 MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-600
Weight: 71.5 lbsApplication/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 100 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V -
Com-Power LI-3P-163 150kHz - 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-599
Weight: 52.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 63 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V -
Com-Power LI-3P-116 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-597
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 16 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705VCISPR 16-1-2: YesDO-160F: YesCISPR 22: YesFCC: YesANSI C63.4: Yes$395.00 -
Com-Power LI-1100C Line Impedance Stabilization Network 150 kHz to 30 MHz
SKU: sku-17
Weight: 17 lbs. / 7.7 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 100 Amps (AC), 70 Amps (DC)Dimensions: 10 x 10 x 21 inches /25.4 x 25.4 x 53.3 cmFrequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets - Input: 120 VAC 60Hz, Output: 12 VDC 1 Amperes (Fan Power Adapter)RF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 440 VAC (Line to Ground), 620 VDC$5,665.00 -
Com-Power LI-215A 9 kHz - 30 MHz LISN w/ NEMA 5-15R Power Output Port
SKU: sku-16
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 25 Amps (AC), 17 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 9 kHz - 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC