SAE J1455

(Showing 3 of 3)

The EMC Shop typically has load dump simulators compliant to SAE J1455 in stock, calibration, equipped with a laptop and software (not standard) and ready to ship that day. Rent, buy or lease SAE J1455 Load Dump Test Equipment at The EMC Shop, a company specializing in automotive electrical conducted disturbance test solutions. Check out all of our Automotive EMC Test Equipment solutions.

SAE J1455 Load Dump Test Equipment

 

  1. SAE J1455 Load Dump Test EquipmentTransient Generators with Coupling Capability
    1. 50 Amps
    2. 100 Amps
    3. 200 Amps
  2. Software with Test Standards Library for easy setup and testing.
  3. Calibration Documentation with Data
  4. User Manual

SAE J1455 Test Equipment, Systems & Solutions

  • EM Test LD 200N Load Dump Generator for ISO 16750-2

    SKU: sku-817

    Output: +/- output Safety laboratory connectors Coupling To the battery +lineDecoupling Via diodeDUT supply Max. 80V/30A
    Freestyle Mode Micropulses: Rise time 1us 10us - 90us with 10us steps 100us - 900us with 100us steps 1ms - 10ms with 1ms steps Pulse duration 10ms - 1,200ms Int. resistor 0.5ohm - 38ohm, in steps of 0.1ohm
    Test Standards: ISO 7637-2 Pulse 5b for 12V and 24V, ISO/WD 16750 Pulse 5b, and much more
    Test Routines: Quick Start, User Defines Routines, Standards Test Routines Service
    $1,690.00
    Typically In Stock
  • EM Test Automotive Test System for ISO 7637-2

    SKU: sku-596

    AS PER ISO 7637-2 THE FOLLOWING STANDARDS CAN BE COVERED: SAE J1113, GM 3097, BMW, Volkswagen, PSA, Chrysler PF 9326, DC 10614, Renault, FIAT, Mitsubishi, Honda, Ford ES-XW7T,
    Electrical Fast Transients: EFT/Burst module for test pulses 3A/3B
    Freestyle Mode Micropulses: Programmable Rise time 1us - 10us in steps of 1us; Pulse duration 50us - 10,000us; Int. resistor 2ohm - 100ohm in steps of 5ohm; 200ohm, 400ohm and 450ohm
    Input: DUT supply +/- DC voltage from VDS 200N or any other DC supply; Pulse 5, 7 From one LD 200N
    Micropulse: Micropulse module for test pulses 1, 2A and 6
    Trigger: automatic, manual, external, battery switch
    UCS 200N Models: Built-in coupling/decoupling networks: UCS 200N50, 80V/50A, 100A@500ms; UCS 200N100, 80V/100A, 150A@500ms; UCS 200N150, 80V/150A UCS 200N200 80V/200A
    Verification: As per Annex C of ISO 7637-2:2011 into 50ohm and 1,000ohm load
    Inquire for availability