Teseq CDN ST08 Coupling Decoupling Network
SKU: 8413
Frequency Range: 10 kHz to 80 MHzApplication: CDN for screened eight lines with RJ45 connectorCurrent Rating: 1000 mAEUT Connector: BNC 50 ΩCommon mode impedance (EUT Port) 10 kHz to 26 MHz: 150 Ω ±20 ΩCommon mode impedance (EUT Port) 26 MHz to 80 MHz: 150 Ω +60 Ω /-45 ΩRF Voltage: <20 V$1,600.00Typically in Stock -
Schwarzbeck CDN S19 HDMI Coupling Decoupling Network
SKU: 8418
Frequency Range: 150 kHz - 230 MHzMax. RF Test Voltage: 30 VMax. RF Input Power: 6 W (continuous)RF Input Connector: 50 Ω BNC femaleEuT, AE Connectors: HDMI femaleIn Stock -
-
-
Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6
SKU: 10828
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$1,190.00 -
Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-399
Weight: 1.9 Lbs (0.86 kg)Application/Test Type: For coupling and decoupling of interference signals on screened linesCurrent Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Teseq CDN S Series Coupling Network for Screened or Coaxial Cables
SKU: 4255
Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$710.00 -
EM Test (Lüthi) CDN S-Type Series Coupling/Decoupling Networks (VGA, HDMI, RJ45, Sub-DXX)
SKU: sku-149
Application/Test Type: Coupling/decoupling networks for Conducted immunity, for screened cables: 8 lines, 9 lines, 15 lines, 25 lines, 37 lines, 50 linesCurrent Rating: 0.25 Amps, 1.5 AmpsFrequency Range: 150 kHz - 230 MHzMains & EUT Connections: VGA, HDMI, RJ45, Sub-DXX connectorsStandards Met: IEC / EN 61000-4-6Voltage Rating: 125 Volts AC/DC -
EM Test (Lüthi) CDN USB 3.0 9-Line Coupling Network, 100 Volts, 150kHz - 230 MHz
SKU: sku-148
Application/Test Type: Coupling/decoupling networks for Conducted immunity, screened lines (coaxial cable)Current Rating: 1 Amps, 1.5 Amps, 3 AmpsFrequency Range: 150 kHz - 80 MHz (USB: 150 kHz - 230 MHz)Mains & EUT Connections: BNC, USB, Sub-D9Standards Met: IEC / EN 61000-4-6Voltage Rating: 100 Volts AC/DC (125 Volts Sub-D9 model) -
EM Test (Lüthi) CDN S4 4-Line Coupling/Decoupling Network (BNC, USB, Sub-D9)
SKU: sku-147
Application/Test Type: Coupling/decoupling networks for Conducted immunity, screened lines (coaxial cable)Current Rating: 1 Amps, 1.5 Amps, 3 AmpsFrequency Range: 150 kHz - 80 MHz (USB: 150 kHz - 230 MHz)Mains & EUT Connections: BNC, USB, Sub-D9Standards Met: IEC / EN 61000-4-6Voltage Rating: 100 Volts AC/DC (125 Volts Sub-D9 model) -
EM Test (Lüthi) CDN S1 for Screened Coaxial Cable, Single Line (Multiple Connectors, Resitance)
SKU: sku-146
Application/Test Type: Coupling/decoupling networks for Conducted immunity, screened lines (coaxial cable)Current Rating: .25 AmpsFrequency Range: 150 kHz to 300 MHzMains & EUT Connections: BNC, N-Type, SMAStandards Met: IEC / EN 61000-4-6Voltage Rating: 100 Volts AC and DC -
Teseq CDN S751A 75 Ohm BNC RF Coupler for IEC 61000-4-6 Testing
SKU: sku-851
Weight: 1.5 kg (3.3 lbs)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 1000 mA maximumDecoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNC 75 ΩRF Connector: BNC 75 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB ±1 dB to 80 MHz, 10 dB +3, -2 dB from 80 MHz to 230 MHzVoltage Rating: AC max. voltage (line to ground): 250V; DC max. voltage (line to ground): 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$1,245.00