The vehicle power supply circuit positive surge simulator TIS 60T3 is designed according to Toyota TSC0502G, which can be used to evaluate the resistance of the devices to the positive surge voltage that is produced when the battery terminals become disconnected.

It is capable of generating high-frequency pulse (Fig. 15), giant pulse (Fig. 17) and positive pole surge (Fig.19) specified in TSC0502G, featuring easy and intuitive setting design.

Features:

  • 5.7” color touch screen;
  • Satisfy the test requirement of positive surge test specified inToyotaTSC0502G;
  • Built-in DC switch for spark test;
  • Ethernet and RJ45 interface for PC remote control and test report printing;

Application Areas

  • Automotive

 

Test 1: Technical Parameters for High-frequency Pulse Voltage Waveform

Output Voltage (VIp)

73 V±2 Vconnected to 25 Ω±0.5 Ω load

80 V±2 V (connected to 1 kΩ±0.02 kΩ load

Rise Time (tr)

10 μs

Time Constant (τ)

52 μs±5 μs

Pulse Repetition (t)

5 ms

Test Time

10 min

Test 2: Technical Parameters for Giant Pulse Voltage Waveform

Output Voltage (VGP)

100 V±2 Vconnected to 25 Ω±0.5 Ω load

110 V±2 Vconnected to 1 kΩ±0.02 kΩ load

Rise Time tr

1 ms

Time Constant (τ)

0.188 s±0.004 s

Pulse Repetition

1 min

Counter

1-99

Test 3: Technical Parameters for High-frequency Pulse + Surge Voltage

High-frequency Pulse

Pulse Voltage Peak Value (VIp)

73 V±2 Vconnected to 25 Ω±0.5 Ω load

80 V±2 Vconnected to 1 kΩ±0.02 kΩ load

Rise Time (tr)

10 μs

Time Constant (τ)

52 μs±5 μs

Pulse Repetition (t)

5 ms

Surge Voltage

Output Voltage Peak

30 V (+0,-1V)

Pulse Duration

300 ms

Pulse Repetition

1 min

Counter

10 s

Calibration Resistor

25 Ω±0.5 Ω, 1 kΩ±0.02 kΩ

DUT Load(optional)

30 A, 50 A, 75 A, 100 A

General Parameters

Working Power Supply

AC 110V/220V±10%50/60Hz±5% AC 220V 50Hz in mainland China by default

Ambient Temperature

5~ 23

Relative Humidity

25% ~ 70%

Atmospheric Pressure

86 kPa ~ 106 kPa

Dimension

6U

Weight

Approx. 50 kg