EN 50370, Electromagnetic compatibility (EMC) for the product family machine tools; immunity and emissions. The EMC Shop stocks a variety of multi-function transient generators, coupling/decoupling networks, and more for all your electromagnetic compliance testing needs.

Get Application Support, Pricing, Lead Time and More: Contact Form

  • Teseq

    SKU: sku-221

    Teseq CDN 3083-Burst 1000 Volt, 100-200 Amp Coupler for EFT/Burst

    Weight: 11 kg (24 lbs)
    Application/Test Type: EFT/Burst testing of equipment requiring large currents, specially designed for heavy industry, smart grid and electro vehicle applications.
    Current Rating: 100 Amp or 200 Amp continous depending on model
    Dimensions: 430 x 310 x 190 mm
    Mains & EUT Connections: SHV; Screw terminals, rated for 200 A
    Standards Met: IEC / EN 61000-4-4 up to 8.8 kV
    Voltage Rating: 690 V AC RMS; 1000 VDC
  • Teseq

    SKU: sku-219

    Teseq CDN 3063-S100 Automated Surge CDN Coupler - 3 Phase, 100 Amp, 480 Volts

    Weight: 100 kg (220.5 lb)
    Application/Test Type: Automated Surge Testing for EUT up to 100 Amps, 480 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
    Current Rating: 3 x 100 Amp continuous (peak 3 x 150 Amp for 30 min.)
    Dimensions: 570 x 840 x 630mm (22.4 x 33 x 24.8")
    Frequency Range: DC – 65 Hz with no loss, 400 Hz max. with power loss
    Mains & EUT Connections: HV-surge pulse input from generator (Fischer connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)
    Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
    Voltage Rating: EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range, up to 225 VDC – up to 7 A
  • Teseq

    SKU: sku-182

    Rent Teseq NSG 3060 for Surge, EFT/Burst, Dips/Interrupts, and Ring Wave up to 6.6 kV

    1 review

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Coupling: ANSI / IEC / external
    Coupling-2: ANSI / IEC / external
    Dips, Interrupts & Variations: From EUT voltage input to 0 V, 0%
    Impedance: 12/30/200 Ω
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Phase synchronization-2: asynchronous, synchronous 0 to 359º (in 1º steps)
    Phase synchronization-3: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: positive / negative / alternate
    Polarity-2: positive / negative / alternate
    Pulse current (short circuit): ±16.6 to ±550 A, ±10%; ±6.6 to ±220 A, ±10%; ±1 to ±33 A, ±10%
    Pulse repetition: 10* s, up to 600 s (in 1 s steps) * see datasheet for derating info
    Pulse voltage (open circuit): ± 200 V to 6.6 kV (in 1 V steps)
    Repetition time: 40 μs to 35 min, 1 to 99’999 cycles
    Test duration: 1 s to 1000 h
    Test duration-2: 1 s to 70’000 min, 1 to 99’999 events, continuous
    Test duration-3: 1 to 9999 pulses, continuous
    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: 100 Hz to 1000 kHz
    Burst time: 1 μs to 1999 s, single pulse, continuous
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling-3: ANSI / IEC / external
    Dips, Interrupts & Variations-2: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Event time: 20 µs to 1999 s, 1 to 300 cycles or 1 to 3’000 1/10 cycles
    Impedance-2: 2/12 Ω
    Phase synchronization-4: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity-3: positive / negative / alternate
    Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit; ±100 V to 2.4 kV (50 Ω matching system)
    Pulse current (short circuit)-2: ±100 A to 3.3 kA
    Pulse repetition-2: 10* s, up to 600 s (in 1 s steps) * see datasheet for derating info
    Pulse voltage (open circuit)-2: ±200 V to 6.6 kV (in 1 V steps)
    Repetition time-2: 1 ms to 4200 s (70 min)
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Switching times: 1 to 5 μs (100 Ω load)
    Test duration-4: 1 to 9999 pulses, continuous
    Uvar with optional variac: depending on model (VAR 3005)
    Uvar with step transformer: 0, 40, 70, 80% (INA 650x)