MIL-STD-461 RS101 Test Equipment, Systems & Solutions
-
-
-
Teseq ITS 6006 Radiated Immunity Test System
SKU: sku-1290
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 ΩReference frequency: 10 MHzMax. adjustment deviation: ±50 Hz$18,000.00In Stock -
RL200K Radiating Loop Sensor for MIL-STD-461D/RS101
SKU: sku-2146
Weight: Radiating Loop: 2 pounds (0.9 kg) Loop Sensor: .25 pounds (0.11 kg)# of turns: Radiating Loop: 20 Loop Sensor: 51Antennas: Loop AntennasConnector: Radiating Loop: Binding posts Loop Sensor: BNCConstruction: Radiating Loop: Wire: 12 AWG, Loop Sensor: Wire: 30 AWG, Shielding: ElectrostaticDimensions: Radiating Loop: 4.72" diameter (12 cm) Loop Sensor: 1.574" diameter (4.0 cm)General Data: Technical Details -
Schloder MGA 1030 DC - 250 kHz Magnetic Field System
SKU: sku-789
Weight: approx. 40 kgDimensions: 449 mm / 177 mm / 580 mmMagnetic Field Strength: 1000 A/mMax input power: 100 V continuous (attenuator autoset at overvoltage) 10 V at 50 ΩStandards Met: IEC / EN 61000-4-8 - SAE J 1113-2, SAE J 1113-22 - GM W 3097 - ISO 11452-8 - Ford ES-XW7T-1A278-AC - MIL-STD-461 E/F RS 101, CS101 - PSA B21 7110 - DC – 11224, DC 1014 - and similar standards -
Com-Power RS101 Loop Antenna Set for MIL-STD-461 RS101 Calibration & Test
SKU: sku-675
Weight: 2.46 lbsFrequency Range: 30 Hz to 100 kHzRF Connector: BNC, FemaleStandards Met: MIL-STD-461 RE101 -
Solar Type 9230-1 Radiating Loop and Type 9229-1 Loop Sensor for MIL-STD-461D/RS101
SKU: sku-501
Weight: Radiating Loop: 2 pounds (0.9 kg) Loop Sensor: .25 pounds (0.11 kg)# of turns: Radiating Loop: 20 Loop Sensor: 51Antennas: Loop AntennasConnector: Radiating Loop: Binding posts Loop Sensor: BNCConstruction: Radiating Loop: Wire: 12 AWG, Loop Sensor: Wire: 30 AWG, Shielding: ElectrostaticDimensions: Radiating Loop: 4.72" diameter (12 cm) Loop Sensor: 1.574" diameter (4.0 cm)General Data: Technical Details -
Solar Type 7429-1 Loop Antenna for RS01 Magnetic Field Tests
SKU: sku-500
Weight: 2 pounds (0.9 kg)# of turns: 10Antennas: Loop AntennasConnector: Binding postsConstruction: Wire: 16 AWGDimensions: 4.72" diameter (12 cm)General Data: Technical Details -
Teseq ITS 6006B Radiated Immunity Test System 80 MHz to 6 GHz
SKU: sku-498
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 Ω -
Em Test CWS 500N3 Test Generator for Mil-STD-461, ISO 11452 and More
SKU: sku-253
Weight: Approx. 36kgAmplifiers: low-frequency signal source with amplifierDimensions: 19"/6HU (555mm x 448mm x 286mm)Frequency range: 10Hz - 250kHzGeneral Data: Technical DetailsHarmonic Distortion (THD): less than -20dBc at 100W power 0.5ohmOperating Temperature: 10°C - 40°CSignal current: Max. 15A rmsSignal level: 0.001V - max. 7Vrms (14Vrms)Signal power: 100W (nominal)Supply Voltage: 115V or 230V +10/-15%, 50/60Hz