ANSI (IEEE) C62.41

(Showing 11 of 11)

The EMC Shop specializes in conducted immunity testing and failure analysis. Rent, buy or lease ANSI (IEEE) C62.41 Surge Immunity Testing Equipment.

ANSI (IEEE) C62.41 Surge Immunity Testing Equipment

ANSI (IEEE) C62.41 Surge Generators - 100 kHz Ring Wave, Combination Wave, Burst EFT, Long Wave

  • 3ctest

    SKU: sku-595

    3ctest RWS 600 Ring Wave Simulator up to 6.0 KV for IEC 61000-4-12

    Weight: Approx. 35Kg
    Dimensions: 19 inch/6U
    Display Interface: 5.7 inch TFT touch screen
    General Data: Technical Details
    Impedance: 12ohm, 30ohm automatic switch
    Max input power: 200W
    Phase synchronization: 0°-360°, 1° step or random
    Polarity: Positive. negative, alternating
    Pulse current (short circuit): 500A ± 10% at 12Ω; 200A ± 10% at 30Ω
    Pulse voltage (open circuit): 0.25 kV–6.0kV ± 10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Test duration: 1s-99s
  • Haefely

    SKU: sku-544

    Haefely PIM 110 Ring Wave Immunity System for IEC 61000-4-12

    Weight: 44 lbs (29 kg net weight)
    Dimensions: 45 x 17 x 57 cm (W x H x D)
    General Data: Technical Details
    Impedance: 12, 30 & 200 Ohms
    Phase synchronization: 1° steps ±1° @50Hz
    Polarity: Positive. negative, alternating
    Pulse repetition: 12 per minute
    Pulse voltage (open circuit): 0.20 – 7.8kV ±10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Test duration: 5 seconds
  • Thermo Keytek

    SKU: sku-321

    Thermo Keytek ECAT Transient Generator System

    Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
    Pulse repetition: 1 shot/9 seconds
    Pulse voltage (open circuit): 200V - 6.6kV ± 10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
  • Teseq

    SKU: sku-219

    Teseq CDN 3063-S100 Automated Surge CDN Coupler - 3 Phase, 100 Amp, 480 Volts

    Weight: 100 kg (220.5 lb)
    Application/Test Type: Automated Surge Testing for EUT up to 100 Amps, 480 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
    Current Rating: 3 x 100 Amp continuous (peak 3 x 150 Amp for 30 min.)
    Dimensions: 570 x 840 x 630mm (22.4 x 33 x 24.8")
    Frequency Range: DC – 65 Hz with no loss, 400 Hz max. with power loss
    Mains & EUT Connections: HV-surge pulse input from generator (Fischer connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)
    Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
    Voltage Rating: EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range, up to 225 VDC – up to 7 A
  • Thermo Keytek

    SKU: sku-799

    Thermo Keytek E510A 10kV Surge Generator

    Coupling: Model E4551 - Single Phase 16 Amps
    Test duration: 1.0ms to 20ms; 1.0ms resolution or 1 to 200 pulses
    Coupling-2: 1 PH / 15 (16) Amps
    Phase synchronization: ±15° with optional coupler/decoupler
    Pulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%
    Pulse repetition: 1 shot/18 seconds
    Pulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt steps
    Repetition time: Adjustable from 300ms to 5s; 1ms resolution
    Typically In Stock
  • 3ctest

    SKU: sku-797

    3ctest CWS 800 8kV Surge Combination Wave Simulator for IEC/EN 61000-4-5 up to 8 kV

    Weight: Approx 30 kg (66 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: Single Phase Built in, 16A, 250VAC, 120VDC
    Dimensions: 19 inch/6u
    Impedance: 2 Ohm
    Mains & EUT Connections: 4mm banana plug
    Phase synchronization: 0°-360°, 1°step or random
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 0.1kA-3kA ±10%
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.2kV - 8kV ±10%
    Standards Met: IEC 61000-4-5, UL1449 and more
  • Haefely

    SKU: sku-297

    Rent Haefely PIM 100 Combination Wave Impulse Module for IEC 61000-4-5 and ANSI C62.41

    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 3 Phase - 32 Amps, 690 VAC
    Dimensions: 45 x 20 x 57 cm
    Impedance: 2 Ohms
    Phase synchronization: 1° steps
    Polarity: pos / neg
    Pulse current (short circuit): 0.1 – 3.7 kA ±10% (8 us ±20% risetime)
    Pulse repetition: 10 seconds / 6 per minute
    Pulse voltage (open circuit): 0.2 – 7.4kV ±10% (1.2 us ±30% risetime)
    Standards Met: IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45
    Test duration: 50 us ±20% (Voltage) ; 20 us ±20% (Current)
  • 3ctest

    SKU: sku-798

    3ctest CWS 1000N 10kV Surge Generator for IEC/EN 61000-4-5

    Weight: Approx 44 kg (97 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Dimensions: 19 inch/6u
    Impedance: 2 Ohm
    Phase synchronization: 0°-360°, 1°step or random
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 0.1kA-5kA ±10%
    Pulse voltage (open circuit): 0.2kV - 10kV ±10%
    Standards Met: IEC 61000-4-5
  • EM Test

    SKU: sku-693

    EM Test EFT 500N5 Electrical Fast Transient/EFT/Burst Simulator

    Test Capabilities: EFT Immunity, Medical Devices
    Standards Met: IEC/EN 61000-4-4
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 250 Volts
    Max EUT AC Current (w/ Built in CDN): 32 Amps
    Max EUT DC Voltage (w/ Built in CDN): 270 Volts
    Max EUT DC Current (w/ Built in CDN): 32 Amps
    EFT/Burst Pulse Output Capability: 4.8 kV
    External Coupling: Data Lines & 3 Phase EUT
    INQUIRE