CISPR 16 LISN's

(Showing 12 of 19)

Skip to 3-Phase LISN's

The EMC Shop specializes in immunity and emissions compliance testing, evlaution and consulting for product developers, electrical engineers and other R&D work. While LISN's aren't essential for precompliance testing and product debugging, utilizing them to ensure consistent impedance throughout will help ensure reliable and consistent test data. Rent, buy or lease CISPR 16 LISN's - Line Impedance Stabilization Networks. 

Show 12

CISPR 16 LISN's Test Equipment, Systems & Solutions

  • Schwarzbeck NNLK 8121 100 Amp Line Impedance Stabilization Network

    SKU: 10857

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 100 Amperes
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Frequency Range: 9 kHz - 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    Typically In Stock
  • EMCO (ETS-Lindgren) 3810-2 LISN, NEMA, 9 kHz - 30 MHz, 10 Amps

    SKU: 11287

    Weight: 10.7 lbs. / 4.9 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 10 Amps
    Dimensions: 8.7 x 15 x 6 inches / 22.2 x 38.1 x 15.2 cm
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 µH/250µH
    Mains & EUT Connections: NEMA typical. (SCHUKO and British available upon request)
    RF Connector: 50Ω BNC Monitor
    Standards Met: FCC 15, VDE 0871, VDE 0875
    Voltage Rating: 250 VAC (Line to Ground)
    $195.00
    In Stock
  • LISN-CISPR16-32A Line Impedance Stabilization Network

    SKU: 6054

    EUT Current Handling: 32 Amps
    Line Voltage: It can be operated with any supply voltage which does not exceed 540V/260V, 50Hz/60Hz. It is also suitable for DC operation.
    Services Available: ISO 17025 Calibration, Rentals, Leases, Purchases, Repairs, Eval/Characterization
    Test Standards: CISPR 16-1-2, VDE 0876, FCC part 15, MIL-STD 461, ISO 60601-1-2
    Inductance: 50 uH
    $3,950.00
    In Stock
  • Com-Power LI-220C 9 kHz - 30 MHz LISN for CISPR 16-1-2/ANSI C63.4

    SKU: 10878

    Weight: 20.5 lbs / 9.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 20 Amperes AC, 14 Amperes DC
    Dimensions: 16.75 x 15.5 x 7.5 inches / 42.5 x 39.3 x 19 cm
    Frequency Range: 9 KHz - 30 MHz
    Inductors: 250 & 50 microhenry (air-core)
    Insertion Loss: 6 dB to 1 dB
    Isolation: 20 dB to 40 dB
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
    $295.00
    Typically In Stock
  • Teseq NNB 51 Line Impedance Stabilization Network Dual-Line-V-LISN

    SKU: 10154

    Weight: 12 kg (26.5 pounds)
    Application/Test Type: Measure distortion signals on power mains
    Current Rating: 16 Amps Max
    Dimensions: 27.0 cm x 41.8 cm x 27.5 cm
    Frequency Range: 9 kHz to 30 MHz
    Impedance: 50 Ω
    RF Connector: N female, 50 CISPR 16-1-2=Yes"
    DO-160F: Yes
    CISPR 22: Yes
    FCC: Yes
    ANSI C63.4: YesOhms"
    RF Input Voltage: 250 Volts max
    Standards Met: CISPR 16-1-2, MIL-STD-461, FCC Part 15, ANSI C63.4
    $195.00
    RENTAL ONLY
  • PMM L3-100 Three Phase 100 Amp LISN for CISPR 16-1-2

    SKU: 10058

    Weight: 70 kg (154 pounds)
    Current Rating: 100 Amps continuous (125 Amps overload for 5 minutes)
    Dimensions: 465 x 450 x 740 mm (18.3 x 17.7 x 29 inches) - mounted on pallet for mobility
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 Ω // [5 Ω + 50 µH] with 250 µH choke
    Mains & EUT Connections: 125 A plug and socket outlet according to IEC309 standard
    RF Connector: BNC (f)
    Standards Met: CISPR 16-1-2; VDE 0876; FCC part 15; MIL-STD 461F
    Voltage Rating: 230 VAC, 325 VDC (L-PE and N-PE); 400 VAC, 565 VDC (L-L and L-N)
  • Com-Power LI-3P-216 LISN, 9 kHz to 30 MHz, 50/250 uH, 500 VAC

    SKU: 11665

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 16 Amperes
    Dimensions: 19.3” x 13.9” x 2.3"
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    $5,795.00
    SHIPS IN 3-5 DAYS
  • FCC-LISN-50-50-4-02 Line Impedance Stabilization Network

    SKU: 12364-1

    EUT Current Handling: 32 Amps
    EUT Voltage Handling: 540V/260V
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Services Available: ISO 17025 Calibration, Rentals, Leases, Purchases, Repairs, Eval/Characterization
    Test Standards: CISPR 16-1-2, VDE 0876, FCC part 15, MIL-STD 461, ISO 60601-1-2
    Inductance: 5 uH
    Inquire for Availability