Telecom Testing

(Showing 12 of 13)

Telecom Testing EMC requirements for information technology & telecommunication equipment.

The EMC Shop stocks electromagnetic environmental equipment for classes of telecommunication equipment covering all relevant electromagnetic environmental parameters. This Recommendation applies to telecommunication equipment installed in telecommunication centres, outdoor locations and customer premises. This is a basic EMC Recommendation for telecommunications.

Show 12

Telecom Testing Categories

Telecom Testing Test Equipment, Systems & Solutions

  • Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6

    SKU: sku-828

    Weight: 1.5 kg (3.3 lbs)
    Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cables
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 250 mA (CDN ST08 1 Amp)
    Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)
    Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
    Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHz
    Mains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)
    RF Connector: BNC 50 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2
    Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)
    Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)
    $1,190.00
  • Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68

    SKU: sku-776

    Weight: approx. 35kg
    Application/Test Type: Test levels as per FCC part 68
    Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PE
    Dimensions: 19“ / 6HU,
    Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)
    Outputs: 4 mm banana socket
    Polarity: pos / neg / alternate
    Rise time: Less than 2 us
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)
    Trigger of bursts: Automatic pulse release
  • EM Test TSS 500N10 Telecom Surge Generator ITU-T for Enhanced Level Testing up to 10 kV

    SKU: sku-403

    Weight: approx. 37.1 kg (81.8 lbs.)
    AC Power Adapter: Supply voltage 115/230 V +10/-15%
    Dimensions: 19"/9 HU, 420 mm x 448 mm x 500 mm
    Energy Storage Capacitor: 1 uF (Pulse 1.2/50 us) 20 uF (Pulse 10/700 μs) 20 uF (Surge Pulse B)
    Front Time: 1 us ± 30% (Pulse 1.2/50 us) 10 us ± 30% (Pulse 10/700 μs) 9 us ± 30% (Surge Pulse B)
    Pulse Duration: 50 us ± 20% (Pulse 1.2/50 us) 700 us ± 20% (Pulse 10/700 us) 720 us ± 20% (Surge Pulse B)
    Standards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.21 ITU-T K.28 ITU-T K.45 (and more)
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 500 V - 10,000 V ± 10%
  • 3ctest CDN 405AF8 Surge Coupling/Decoupling Network for Data Lines

    SKU: sku-339

    Application/Test Type: Test low-speed communication lines against lightening surge as per figure 12 in IEC/EN61000-4-5 edition 3
    Coupling: 4 pair unshielded assymetric lines
    Current Rating: Max 1 A
    Impedance: 200Ω ±5%
    Inductors: 20 mH Decoupling
    Input: 1.2/50us, 10/700us
    Mains & EUT Connections: RJ45 female
    Standards Met: IEC 61000-4-5 Ed. 3
    Test Voltage: 6kV (10kV, customized)
    Voltage Rating: 90 VDC
  • 3ctest CWS 600 6kV Surge Simulator for IEC 61000-4-5

    SKU: sku-331

    New Systems: Inquire to purchase a new unit
    Coupling: Single Phase Built in, 16A, 250VAC, 120VDC
    Applications: EMC Surge, CE Marking
    Mains & EUT Connections: 4mm banana plug
    Polarity: Positive, Negative, Alternate
    Pulse current (short circuit): 0.1kA-3kA ±10%
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.2kV - 6kV ±10%
    $1,275.00
    In stock
  • EM Test NX5 Compact EMC Generator for EFT/Burst, Surge & Power Fail

    SKU: 10547

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Max EUT Voltage (w/ Built in CDN): 300 Volts
    Max EUT Current (w/ Built in CDN): 16 Amps
    Peak inrush current capability: 500 Amps (up to 2.5 kA)
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 5 kV
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
    Dips, Interrupts & Variations: 16 Hz - 500 Hz and DC
    Typically In Stock
  • Haefely DEC 6 Decoupling Network for Symmetrical Data and Control Lines

    SKU: sku-409

    Weight: approx. 2 kg net
    Coupling: Decoupling elements Resistors 200 Ohm
    Dimensions: 30 x 20 x 16 cm (w x h x d)
    DUT current: Current on EUT lines max. 0.1A
    Pulse amplitude: max. 6.6kV
    Pulse Shape: 10/700us -5/320us 1.2/50us - 8/20us 100kHz ring wave
    Test Voltage: Voltage on EUT lines max. 72V DC or 50V AC,RMS (with gas arrestors as protection elements) max. 144V DC or 100V AC,RMS (with ABDs as protection elements)
    In Stock
  • 3ctest CWS 600CT Combination Wave & Telecom Surge Simulator, 1.2/50us 8/20us 10/700us 5/320us

    SKU: sku-333

    Polarity: Positive, Negative or Alternate
    Weight: Approx 15 kg (33 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1-999
    Coupling: Optional for external SPN series CDN's
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Impedance: 2 phm, Optional 12 ohm and 500 ohm
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity-2: Positive, Negative and Alternating
    Pulse current (short circuit): 0.15 kA–3.0kA ±10% (2ohm)
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.3kV–6.0kV ±10%
    RF Connector: BNC, 5VTTL
    Standards Met: UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: 6s-99s
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,