Combination Wave/Surge Generators

(Showing 11 of 23)

The EMC Shop stocks combination wave surge generators for conducted immunity testing and compliance according to IEC 61000-4-5. UL 1449, ANSI C62.41 and more.

 

See - Surge Immunity Test, Setup, Equipment

Conducted
Immunity & Susceptibility

Parameters Specifications
Standard

IEC 61000-4-5:2017 and IEC 61000-4-5:2005

Coupling waveform
1.2/50us, 10/700us
Coupled current waveform
8/20us, 5/320us
Pulse voltage
6kV (10 kV, customized)
Coupling mode
Common mode, line to ground
Coupling device
90V gas discharging tube
Output impedance
Current-limiting resistance can be replaced according to test requirements
Communication port
RJ45 female connector to connect telecommunication cable
Pin layout
Pair 1: pins 1 / 2 Pair 2: pins 3 / 6 Pair 3: pins 4 /5 Pair 4: pins 7 / 8
Data rate
10MBit/s, 100MBit/s, 1,000MBit/s
Working voltage
DC:3-12V
Working current
Max. 1A
Residual voltage
<15% of coupling surge voltage

Show 12

Combination Wave/Surge Generators Test Equipment, Systems & Solutions

  • EMC Partner MIG1206 12kV Surge Generator

    SKU: 6527

    Standards Met: IEC 60950, IEC 60065 and IEC 62368-1
    Applications: EMC Surge, CE Marking
    Max EUT AC Voltage (W/ Built In CDN): 480 Volts
    Max EUT AC Current (W/ Built In CDN): 32 Amps
    Max EUT DC Voltage (W/ Built In CDN): 110 Volts
    Max EUT DC Current (W/ Built In CDN): 25 Amps
    Combination/Wave Surge Output Capability: 12.5 kV
    External Coupling: Data Lines (Surge), 3PH EUT
    IN STOCK
  • Haefely PIM 100 Combination Wave Impulse Module

    SKU: 10297

    Output: Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse) up to 7.8kV
    Coupling (Max EUT Power): 3 Phase - 100 Amps, 690 VAC
    Test Standards: IEC/EN 61000-4-5 Ed. 1 & 2, ANSI C62.45
    Pulse current (short circuit): 0.1 – 3.7 kA ±10% (8 us ±20% risetime)
    Pulse repetition: 10 seconds / 6 per minute
    Features: Impulse voltage and current monitors
    In Stock
  • EM Test VCS 500 M10 10kV Combination Wave Surge Immunity Generator

    SKU: sku-1287

    Weight: approx. 35kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Dimensions: 19"/6HU;
    Mains & EUT Connections: External Coupler Only
    Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
    Polarity: pos / neg / alternate
    Pulse current (short circuit): max. 5,000A ± 10%
    Pulse repetition: 1s - 999s, depending on the voltage
    Pulse voltage (open circuit): 500V - 10,000V ± 10%
    Supply Voltage: 115/230V +10/-15%
    Test duration: 1 - 30,000 or endless
  • Haefely PSURGE 4010 Surge Generator for IEC 61000-4-5 Testing

    SKU: sku-574

    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5
    Polarity: positive, negative, alternating
    Pulse current (short circuit): 100 Amps to 2.1 kA
    Pulse repetition: up to 12 per minute
    Pulse voltage (open circuit): 200 Volts to 4.2 kV
    Standards Met: EN/IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2 (IEC 61000-4-9 w/ MSURGE)
  • Thermo Keytek ECAT Transient Generator System

    SKU: 11321

    Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
    Pulse repetition: 1 shot/9 seconds
    Pulse voltage (open circuit): 200V - 6.6kV ± 10%
    Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
    Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
    In Stock
  • 3ctest SG 5010H 10kV Surge Simulator for IEC 61000-4-5, GB/T, ITU-T K21/K44

    SKU: sku-326

    Polarity: +/-, positive first or negative first
    Weight: Approximately 300 kg
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 1 or 3 Phase 16 Amps 250V/450V
    Impedance: 500Ω±10%
    Input voltage UIN: AC220V±10%,50/60H
    Output Current: 10/700 and 5/320±20%μs
    Polarity-2: +/-, positive first or alternate
    Pulse current (short circuit): 150A - 3kA/5kA (±10%)
    Pulse voltage (open circuit): 300V - 6kV/10kV (±10%)
    Standards Met: EN/IEC 61000-4-5, IEC 61643-1, GB/T 17626.5m GB/T 16927.1, ITU-T K21 and ITU-T K44
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: Voltage - 50μs(±20%); Current - 20μs(±20%)
    Test Voltage: 300V~6Kv/10kV (±10%)
    Transfer Impedance: 15Ω、40Ω(25+15Ω
  • Rent Haefely PSURGE 4010 Surge Generator for IEC 61000-4-5 Testing

    SKU: sku-280

    Test Standards: EN/IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2 (IEC 61000-4-9 w/ MSURGE)
    Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5
    Pulse current (short circuit): 100 Amps to 2.1 kA
    Pulse repetition: up to 12 per minute
    Pulse voltage (open circuit): 200 Volts to 4.2 kV
    $895.00
  • 3ctest CWS 600CT Combination Wave & Telecom Surge Simulator, 1.2/50us 8/20us 10/700us 5/320us

    SKU: sku-333

    Polarity: Positive, Negative or Alternate
    Weight: Approx 15 kg (33 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1-999
    Coupling: Optional for external SPN series CDN's
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Impedance: 2 phm, Optional 12 ohm and 500 ohm
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity-2: Positive, Negative and Alternating
    Pulse current (short circuit): 0.15 kA–3.0kA ±10% (2ohm)
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.3kV–6.0kV ±10%
    RF Connector: BNC, 5VTTL
    Standards Met: UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: 6s-99s
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,
  • 3ctest CWS 600T 10/700us Telecom Wave Surge Simulator for IEC 61000-4-5

    SKU: sku-330

    Weight: Approx 15 kg (33 lbs)
    Counter: 1-999
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity: Positive, Negative or Alternate
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    RF Connector: BNC, 5VTTL
    Standards Met: IEC 61000-4-5 and ITUETSI
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.