Overview
The RFCP500M EMI Current Probe is designed to permit field intensity meters, spectrum analyzers, and other 50 ohmimpedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multiconductor cables, ground and bonding straps, shielded conduits and on coaxial cables.
For ease and convenience of performing conducted measurements, all of our current probes utilize the split type clamp-on design. Small and lightweight, each Current Probe is manufactured to exacting standards, thus insuring repeatable performance.
RFCP500M EMI Current Probe Specifications:
- Transfer impedance (ZT): 1.0 to 5.0 Ω above 300 kHz
- Output load impedance: 50 + j 0 Ω
- Continuous signal current (CW): 40 A
- Maximum power current: 200 A DC to 400 Hz
- Maximum power voltage: Limited by the conductor under test
- Peak pulse current: 60 A maximum
- Probe circuit: Inserted primary toroidal transformer
- Connector: Type "N" female
- Style: Clamp on
- Weight: 1.2 pounds (0.55 kg)