Com-Power Turn Key Conducted Immunity Test System up to 250 MHz

Condition:
New
Coupling:
Directional Coupler DCD-1000-100W
Frequency Capabilities:
150 kHz to 250 MHz
PC Software:
CSAT 2.xx
Standards Met:
61000-4-6
Manufacturer:
Com-Power
Online Orders Ship Same Day

 

Availability:

Typically In Stock

SKU:
11391

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Com-Power Turn Key CIS Description:

The Com-Power CIS series of Conducted immunity system specifically geared for use in IEC 61000-4-6 immunity testing using coupling decoupling networks (CDN).The system can be customized include the CDNs to fit your application at the time of purchase.

The CIS-series systems test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes ACS series power amplifier, Coupling Decoupling Network (CDN), directional couplers, attenuators, cables and CSAT software. These systems when properly configured are capable of testing your products to the all levels given in IEC 61000-4-6 up to 230 MHz.

Before you begin testing with the CDN you will need to establish a calibrated drive levels corresponding to the test levels. Accessories such as ADA-515, TEP-050 and ADA-xx shorting adapters are needed for calibration is included with each system. When used with compatible signal generator and spectrum analyzer and the CSAT test software can fully auto - mate this calibration and also perform the test. All Com-Power CDNs are calibrated to meet the latest CISPR 16 test standards.

Application:

The required test levels per IEC 61000-4-6 (given in the table below) that can be acheived using the ASC series power when properly configured with a compliant coupling decoupling network from Com- Power or another manufacturer. Please refer to IEC 61000-4-6 for information on test setup, procedures and test accessories needed.

Test Level Volts (V) umr (150) Volts umr (150) Volts
1 0.167 -2.5
2 0.5 7
3 1.67 17.5

V o = Open circuit voltage in 150? system.

umr = Voltage level measured at the output of the 150? to 50? adapter (ADA-515).

The IEC-61000-4-6 requires that an appropriate coupling decoupling networks (CDN) with defined common mode impedance be used for coupling and/ or decoupling purposes on any type of power or I/O interface for which a CDN is suitable and available. Com-Power has a wide selection of CDNs.

Com-Power CIS Specifications:

Description

CIS-25

CIS-50

CIS-100

RF Power Amplifier

ACS-230-25W

ACS-230-50W

ACS-250-100W

Coupling Decoupling Networks

CDN-xx

CDN-xx

CDN-xx

Directional Coupler

DCD-1000-100W

DCD-1000-100W

DCD-1000-100W

Shorting Adapter*

ADA-xx

ADA-xx

ADA-xx

Attenuator

ATTN-6-100W

ATTN-6-100W

ATTN-6-100W

Attenuator

ATTN-30-100W

ATTN-30-100W

ATTN-30-100W

Software

CSAT 2.xx

CSAT 2. xx

CSAT 2.xx

Cable set

CIS-CB4

CIS-CB4

CIS-CB4

Key Considerations

Manufacturer:
Com-Power
Coupling:
Directional Coupler DCD-1000-100W
Frequency Capabilities:
150 kHz to 250 MHz
PC Software:
CSAT 2.xx
Standards Met:
61000-4-6

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.