3ctest APS60F30D Overview
- Pre-programmed test routines to simulate various supply waveforms
- To simulate various supply waveforms, e.g. superimposed noise
- Test current up to 30A
- Quick response, the bandwidth up to 300 kHz
- Pulses 4 and 2b as per ISO 7637-2:2004
- Voltage variation test as per ISO 16750-2/a
- Automatic voltage compensation with external control of simulated input waveform
- Ethernet, RJ45, PC control, and test report documentation and print
- 5.7 inch color touch screen
The 3ctest APS60F30D 4-Quadrant Power Supply/Amplifier can be used as battery supply simulation and DC voltage source. During test in test lab, APS series can replace vehicle battery. Pulse 2b, Pulse 4, sine wave noise and other complicated voltage variation tests can be conducted by the APS series simulator as per ISO 7637/16750-2. It can simulate multiple battery supply waveforms as per international standards and multiple automotive manufacturer standards. Also, as a powerful DC source, it can supply power for DUT during automotive transient pulse test, which can meet three kinds of supply voltage. The system can also be used as power amplifier for magnetic field immunity test.
[split]
General Data | ||||
APS 60F10D+DCP 60F10D | APS 60F20D+DCP 60F20D | APS 60F30D+DCP 60F30D | APS 60C30F.1+DCP 60C30F.1 | |
Output current | 0 A - 10 A, continuous | 0 A - 20 A, continuous | 0 A - 30 A, continuous | 0 A - 30 A, continuous |
Peak current | 20 A for 200 ms | 40 A for 200 ms | 60 A for 200 ms | 60 A for 200 ms |
Frequency range | DC - 150 kHz full signal | DC - 150 kHz full signal | DC - 150 kHz full signal | DC - 150 kHz full signal |
Basic Equipment | ||||
Simulator, test cable, power cord, fuse, factory test report, warranty report and user manual | ||||
Output voltage | MAX 80V | |||
Voltage resolution | ±0.2V | |||
Output current | MAX 30A | |||
Analog signal input | BNC | |||
Sense signal input | BNC | |||
Source impedance | 10mΩ | |||
Voltage compensation resolution | ±0.1V | |||
Max. compensated voltage | 4V | |||
Voltage deviation | 1V (resistive load, including impulse current), recover to 63% of max. amplitude during 100us | |||
Voltage fluctuation | 0.2V P-P, min. frequency: 400Hz | |||
Rise time | 10us(resistive load) | |||
Sine signal output | Frequency up to 300kHz?as per Vpp and output current of waveform | |||
External signal input | 0 ~ ±10V | |||
output | DUT supply: high current connector | |||
Serial port | LAN Ethernet RJ45 | |||
enlarging scale of external signal | 1:10 | |||
Supply voltage | 220VAC | |||
Size | 19’’/8U | |||
Weight | 40Kg | |||
Optional Accessory | ||||
1. PC control software AUTO Lab | ||||
With PC installed WIN XP and WIN7, it can be easily operated to make the measurement, based on the customized test program. It can identify any device for AUTO Lab test with automatic configuration. It can easily generate test reports. | ||||
2. Output voltage 40V products can be customized |