RF Screen Room Test Kit

Condition:
Used
Weight:
26 lb
Frequency Range:
95 kHz (Crystal Controlled)
Output Signal:
Pulse modulated at approximately 600 Hz and has a 50% duty cycle
Receiver:
Two meter scales for high and low operation Aural output for headphone operation Battery operated for portable use Dynamic range of 120dB
Transmitter Output:
1 Ampere RMS into an inductive load from approximately 5–50 μHy
Online Orders Ship Same Day
$7,950.00

 

SKU:
988-PU
Availability:

One Unit Left!


Getting Started...

RF Screen Room Test Kit Overview

The RF Screen Room Test Kit is a service tool which has been designed to determine if the enclosure provids adequate shielding effectiveness. It consists of two main components - a transmitter and receiver. The transmitter is a low power, fixed frequency, crystal controlled transmitter operating at 60 MHz. The receiver is the mated crystal controlled receiver.

The acceptance criteria for shielding effectiveness as determined by the test kit has been set at 50dB, for exampl 52dB is acceptable but 49dB is considered unacceptable. Shielding level approaching 50dB or less indicate an excessive RF leaks are present in the shielded room.

RF Screen Room Test Kit Key Considerations

Weight:
26 lb
Frequency Range:
95 kHz (Crystal Controlled)
Output Signal:
Pulse modulated at approximately 600 Hz and has a 50% duty cycle
Receiver:
Two meter scales for high and low operation Aural output for headphone operation Battery operated for portable use Dynamic range of 120dB
Transmitter Output:
1 Ampere RMS into an inductive load from approximately 5–50 μHy

Connect with The EMC Shop