Teseq CDN M532 5-Line/32 Amp RF Coupling/Decoupling Network

Weight:
6.5 kg
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating:
32 Amps Maximum
Decoupling of Common Mode Disturbance:
Greater than 30 dB
Dimensions:
6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
Insertion Loss:
Greater than 0.1 dB
Mains & EUT Connections:
4 mm, safety (Optional IEC 320 16A)
RF Connector:
BNC, 50 Ω
RF Input Voltage:
Less than 30 V
Standards Met:
IEC 61000-4-6
Voltage Division Factor:
10 dB +3 dB / -1 dB
Manufacturer:
Teseq
Online Orders Ship Same Day

 

SKU:
sku-2093

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Teseq CDN M532 Features:

  • 5 power lines
  • Frequency range: 150 kHz to 230 MHz
  • Designed for IEC/EN 61000-4-6
  • AC Voltage: 300V Line to Ground / 520V Line to Line
  • DC Voltage: 400V Line to Ground / 600V Line to Line
  • Max Current 32 Amps
  • Test Voltage: 3.1 kVDC, 2 seconds
  • 4 mm banana sockets

Teseq CDN M532 Configurations:

  • CDN M32S - Coupling Decoupling Network for IEC 61000-4-6, type M5, 32 A, 230 MHz (banana), 3xL,N,PE with calibration adapter set in storage case, includes 2x CAL U100B, SAR MA51, SAR M500, SAR M116, A 50-N

Key Considerations

Manufacturer:
Teseq
Weight:
6.5 kg
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating:
32 Amps Maximum
Decoupling of Common Mode Disturbance:
Greater than 30 dB
Dimensions:
6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
Insertion Loss:
Greater than 0.1 dB
Mains & EUT Connections:
4 mm, safety (Optional IEC 320 16A)
RF Connector:
BNC, 50 Ω
RF Input Voltage:
Less than 30 V
Standards Met:
IEC 61000-4-6
Voltage Division Factor:
10 dB +3 dB / -1 dB

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.