Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network

Condition:
Used
Weight:
3.3 Lbs (1.5 kg)
Application/Test Type:
switchable 2 or 3 power lines, (L+N or L+N+PE)
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating:
16 Amps
Decoupling of Common Mode Disturbance:
150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
Dimensions:
3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
Frequency Range:
150 kHz to 230 MHz
Insertion Loss:
Less than 0.1 dB
Mains & EUT Connections:
4 mm banana
RF Connector:
BNC 50 Ω
RF Input Voltage:
30 Volts (Max)
Standards Met:
IEC/EN 61000-4-6
Voltage Division Factor:
150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
Voltage Rating:
AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
Manufacturer:
Teseq
Online Orders Ship Same Day
$395.00
SKU:
sku-827-MO-NO

 


 

Availability:

Typically In Stock


Description

About the Teseq CDN M016:

IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Whilst the published standard only specifies the performance of CDN from 150 kHz to 80 MHz, most of Teseq CDNs are specially designed to give the same performance to a wider frequency range. This is required by some product specific standards. Each CDN is also useable for emission testing. Special types meet the requirements of CISPR 15 or can be used as impedance stabilization network (ISN) defined in CISPR 22.

Conducted
Immunity & Susceptibility

Bulk Current
Injection Probes

The EMC Shop Rental & Delivery

Included with the Teseq CDN M016:

  • M016 CDN
  • QTY 2 CAL U100B
  • SAR MA31
  • QTY 2 SAR M300
  • SAR M116
  • A 50-N
  • NIST Calibration with Data
  • Carrying Case
  • User Manual

All those part numbers confusing? Those are all the cal adapters required to get up and running

How to Rent the Teseq CDN M016:

  • Learn more about renting EMC equipment
  • Click "Add to Cart" above
  • Register or Check Out as a Guest
  • Select Shipping Method (use "My Account" and input your account # and method)
  • Order Confirmation and Tracking Info Follows
RFCI-75 RF Conducted Immunity Generator, 100 kHz - 400 MHz
RFCI-75 RF Conducted Immunity Generator, 100 kHz - 400 MHz

Videos

Equipment Specifications

Manufacturer:
Teseq
Weight:
3.3 Lbs (1.5 kg)
Application/Test Type:
switchable 2 or 3 power lines, (L+N or L+N+PE)
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating:
16 Amps
Decoupling of Common Mode Disturbance:
150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
Dimensions:
3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
Frequency Range:
150 kHz to 230 MHz
Insertion Loss:
Less than 0.1 dB
Mains & EUT Connections:
4 mm banana
RF Connector:
BNC 50 Ω
RF Input Voltage:
30 Volts (Max)
Standards Met:
IEC/EN 61000-4-6
Voltage Division Factor:
150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
Voltage Rating:
AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec