Overview
The EM Test (Lüthi) CDN S4 4-Line Coupling/Decoupling Network (BNC, USB, Sub-D9) is a configurable CDN used for shielded signal lines. Please specify configuration under CDN Power Capacity in the order box above.
Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection lines.
For testing conducted RF immunity according to IEC 61000-4-6 and IEC / EN 60945 different types of CDN are required, depending on cable. Specific CDNs are also used for emission measurements according to CISPR 15 and EN 55015.
EM Test (Lüthi) offers a wide selection of appropriate coupling / decoupling networks, and current probes and the associated accessories for standard-compliant calibration.
EM Test (Lüthi) CDN S4 Specifications:
- For 4 screened lines
- AE/EUT: BNC-connectors, USB (A/A) connectors, Sub-D9 connectors
- AC/DC: max. 100-125 Volts / 1-1.5 Amps
- Frequency: 150 kHz - 80 MHz (USB: 150 kHz - 230 MHz)
EM Test (Lüthi) CDN S4 Models:
- CDN S4: CDN for four screened cables, Sub-D9 conn., 125V AC / 125V DC, 1.5A, 150kHz - 230MHz
- CDN S4 BNC: CDN for four screened cables, BNC conn., 100V AC / 100V DC, 1.5A, 150kHz - 80MHz
- CDN S4 USB: CDN for screened cable, four lines, USB A conn., 100V AC / 100V DC, 1A, 150kHz - 230MHz
- CDN S4-3A BNC: CDN for screened cable, four lines, BNC conn., 100V AC / 100V DC, 3A, 150kHz - 80MHz