EM Test (Lüthi) CDN M4 4-Line Coupling/Decoupling Network 3 Phase + Earth/Ground

Application/Test Type:
Coupling/decoupling networks for Conducted immunity, mains AC/DC power supply lines
Current Rating:
up to 100 Amps
Frequency Range:
150 kHz to 300 MHz (150 kHz - 80 MHz at high current)
Mains & EUT Connections:
AE: 4mm safety lab connectors EUT: 4mm safety lab connectors
RF Input Voltage:
30 V (Max)
Standards Met:
IEC / EN 61000-4-6
Voltage Rating:
up to 750 Volts AC and DC
Manufacturer:
EM Test
Online Orders Ship Same Day

 

Description

EM Test (Lüthi) CDN M4 4-Line Coupling/Decoupling Network 3 Phase + Earth/Ground is a configurable CDN allowable for AC power lines testing of L1/L2/L3/PE or N. Please specify configuration under CDN Power Capacity in the order box above.

Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection lines.

For testing conducted RF immunity according to IEC 61000-4-6 and IEC / EN 60945 different types of CDN are required, depending on cable. Specific CDNs are also used for emission measurements according to CISPR 15 and EN 55015.

EM Test (Lüthi) offers a wide selection of appropriate coupling / decoupling networks, and current probes and the associated accessories for standard-compliant calibration.

EM Test (Lüthi) CDN M4 Specifications:

  • For 4 AC supply lines (L1/L2/L3/PE or N)
  • AE: 4mm safety lab connectors
  • EUT: 4mm safety lab connectors
  • AC: max. 3 x 400 V/16 A
  • DC: max. 1,000 V/16 A
  • Frequency 150 kHz - 230 MHz

Options Available

  • Traceable calibration (ISO17025) for IEC 61000-4-6
  • Traceable calibration (ISO17025) for CISPR15 (300 MHz) and IEC 61000-4-6

EM Test (Lüthi) CDN M4 Models:

  • CDN M4 PE: CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 1000V DC, 16A, 150kHz - 230MHz
  • CDN M4 N: CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 1000V DC, 16A, 150kHz - 230MHz
  • CDN M4 PE-32A: CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 1000V DC, 32A, 150kHz - 230MHz
  • CDN M4 N-32A: CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 1000V DC, 32A, 150kHz - 230MHz
  • CDN M4 PE-32A/750V: CDN for four mains supply lines (L1+L2+L3+PE) 3x750V AC, 1000V DC, 32A, 150kHz - 80MHz
  • CDN M4 N-32A/750V: CDN for four mains supply lines (L1+L2+L3+N) 3x750V AC, 1000V DC, 32A, 150kHz - 80MHz
  • CDN M4 PE-75A: CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M4 N-75A: CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 750V DC, 75A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M4 PE-100A: CDN for four mains supply lines (L1+L2+L3+PE) 3x400V AC, 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M4 PE-100A/750V: CDN for four mains supply lines (L1+L2+L3+PE) 3x750V AC, 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M4 N-100A: CDN for four mains supply lines (L1+L2+L3+N) 3x400V AC, 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port
  • CDN M4 N-100A/750V: CDN for four mains supply lines (L1+L2+L3+N) 3x750V AC, 750V DC, 100A, 150kHz - 80MHz, incl. high-current MC connectors for AE and DUT port

Equipment Specifications

Manufacturer:
EM Test
Application/Test Type:
Coupling/decoupling networks for Conducted immunity, mains AC/DC power supply lines
Current Rating:
up to 100 Amps
Frequency Range:
150 kHz to 300 MHz (150 kHz - 80 MHz at high current)
Mains & EUT Connections:
AE: 4mm safety lab connectors EUT: 4mm safety lab connectors
RF Input Voltage:
30 V (Max)
Standards Met:
IEC / EN 61000-4-6
Voltage Rating:
up to 750 Volts AC and DC