Certification Standards

(Showing 12 of 75)
Show 12 24 36 48
  • SKU: sku-2206

    LPA7G 290 MHz - 7 GHz Log Periodic Antenna

    Weight: 1.5 lbs
    Antenna Factor (1 Meter): 15 to 47 db/m
    Antennas: Log Periodic Antennas
    Connector: N-Type, female
    Dimensions: 26.3" x 20.1"
    Frequency Range: 290 MHz - 7 GHz
    Gain: 5.8 dBi
    Impedance: 50 Ohms
    Max Radiated Field Strength: 200 V/m
    Maximum Continuous Power: 1000 Watts
    Mounting Base: ¼ - 20 Thread, female
    VSWR: Typ. 1.65:1
    $4,395.00
  • EM Test

    SKU: sku-2169

    EM Test Surge, EFT, PQF, Ring Wave Immunity System for 3 Phase, 100 Amp EUT

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts, Ring Wave
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-12 IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 480 Volts
    Max EUT AC Current (w/ Built in CDN): 100 Amps (Per Phase)
    Max EUT DC Voltage (w/ Built in CDN): 1000 Volts
    Max EUT DC Current (w/ Built in CDN): 100 Amps
    Peak inrush current capability: 500 Amps
    EFT/Burst Pulse Output Capability: 5.5 kV
    Combination/Wave Surge Output Capability: 6.6 kV
    External Coupling: Data Lines (EFT & Surge)
    Dips & Interrupts: 40%, 70%, 80%; Interrupts - 0% (short and open)
    Ring Wave: 100 kHz, 6 kV
    RENTAL ONLY
  • EM Test

    SKU: sku-1195

    Complete IEC/EN Test Rack for CE Marking and Conducted Immunity Certification

    Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & Variations
    Standards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
    Max EUT AC Voltage (w/ Built in CDN): 264 Volts
    Max EUT AC Current (w/ Built in CDN): 16 Amps
    Max EUT DC Voltage (w/ Built in CDN): 220 Volts
    Max EUT DC Current (w/ Built in CDN): 10 Amps
    Peak inrush current capability: 500 A (at 230 V)
    EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kA
    Combination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)
    External Coupling: Data Lines (EFT & Surge), 3PH EUT
  • EM Test

    SKU: sku-921

    Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6

    Weight: 17 kg (37.5 Pounds)
    Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applications
    Dimensions: 19"/3 HU
    Frequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHz
    Impedance: 50 Ohms
    Input: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)
    Maximum Continuous Power: 80W (nominal)
    Standards Met: IEC 61000-4-6
    Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, Service
    Voltage Rating: 1 V to 30 Volts Max
  • Com-Power

    SKU: sku-892

    Com-Power LI-550C 100 kHz to 108 MHz Line Impedance Stabilization Network

    Weight: 14 lbs. / 6.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 50 Amps (AC), 35 Amps (DC)
    Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cm
    Frequency Range: 100 kHz to 108 MHz
    Inductors: 5 µH (air-core)
    Insertion Loss: 1.5 dB (150 kHz to 30 MHz)
    Isolation: 20 - 40 dB (100 kHz to 3 MHz) 40 dB ( 3 MHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 25 / CISPR 16-1-2
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Thermo Keytek

    SKU: sku-801

    Thermo Fisher Keytek ECAT High Voltage Burst/EFT Generator up to 8 kV

    Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4
    Burst frequency: Adjustable from 1 kHz to 1 MHz up to 4.4 kV; 1 kHz to 250 kHz from 4.4 kV to 8.0 kV
    Burst time: 1 to 360 sec.; 1 second resolution 1 to 240 min.; 1 minute resolution 1 to 24 hours; 1 hour resolution
    Polarity: Positive, negative, alternating
    Pulse amplitude: 200V to 8.0kV, ±10%; 5 V resolution
    Standards Met: IEC 61000-4-4, IEC 61000-4-5, IEEE C62.41, UL 864, ANSI/IEEEC62.41, UL 1449
    In Stock
  • Schloder

    SKU: sku-791

    Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A

    Application/Test Type: unscreened supply lines (mains) AC + DC
    Current Rating: 16A / 32A / 63 A / 100 A
    Dimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on model
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: banana sockets
    RF Connector: 50 Ω BNC (Female)
    Standards Met: IEC / EN 61000-4-6
    Voltage Rating: up to 250 VAC / 400 VDC

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.