Description
The Thermo Scientific (Keytek) EMCPro Plus EMC Test System along with the Keytek Minizap 15kV ESD simulator will allow capabilities for EMC CE Mark and compliance testing to IEC 61000-4-4 (EFT/Burst), IEC 61000-4-5 (Surge) and IEC 610000-4-11 (PQF) standards. The EMCPro Plus is a reliable, seasoned system that has been a flagship for Thermo Scientific (Keytek) for many years.
The Keytek (Thermo Fisher) EMCPro Plus EMC Test System is the only tester capable of monitoring surge voltage and current at the output terminals as opposed to measuring at the generator, which can lead to large errors.
View Thermo-Keytek MZ15/EC Minizap ESD Simulator for IEC 61000-4-2
View Keytek (Thermo Fisher) EMCPro Plus EMC Test System
How to Rent the CE Marking CIS System:
- Click "Add to Cart" above
- Shipping Section - Select "Use My Account" - we ship this system freight to keep it upright. Indicate in the Notes section if you'd like us to facilitate shipment or if your logistics team will do so.
- Checkout Accordingly
- An EMC Shop representative will contact you with shipping estimates or logistics details.
Videos
Custom Field
Coupling 1 phase, 50 - 277 VAC, 16 Amps maximum; 100 Volts, 10 Amps DC
Dips, Interrupts & Variations 40%, 70%, 80%; Interrupts - 0% (short and open)
Weight 39 kg (85 lb)
Air Discharge Voltage Range ±0.5 to 15 kV TRUE-ESD (under 0.3 ns nominal risetime up to 4 kV)
Application/Test Type CE Marking - Safety and EMC Directives
Burst (EFT) 5/50 ns Pulse conforms to IEC/EN 61000-4-4
Burst frequency 1-100 kHz, in 0.5k Hz steps, ±10%
Burst time 15 ms ±20%, for pulse frequencies up to 5 kHz, 0.75 ms above 5 kHz
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse) Pulse conforms to IEC/EN 61000-4-5
Contact Discharge Voltage Range ±0.5 over 8 kV FR/CI™ std under 0.3 ns risetime independent of charge voltage; 3.75A/kV ± 10% peak, e.g. 30 Amps at 8 kV
Coupling-2 1 phase, 50 - 277 VAC, 16 Amps maximum; 100 Volts, 10 Amps DC
Dimensions 22.9 cm (8.7 in) x 43.4 cm (17.1 in) x 64.8 cm (25.5 in)
Dips, Interrupts & Variations-2 Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
Electrostatic Discharge Pulse conforms to IEC 61000-4-2 edition 2
Holding Time Single shot as well as 1/sec and 20/sec repetitive operation
Mains & EUT Connections Nema, British, Schuko
Peak inrush current capability Minimum 250 Amps @ 100 - 120 V, Minimum 500 Amps @ 220 - 240 V
Pre-Programmed IEC Levels Yes
Pulse amplitude 5/50 ns ±30%
Pulse current (short circuit) 125 A - 3.0kA ±10%
Pulse repetition Up to 4 per minute
Pulse voltage (open circuit) 250V - 6.0 kV, 12 mode; 250V - 6.0 kV, 2 mode
Standards Met IEC 61000-4-5, EN 61000-4-5, and IEC 61000-4-11, IEC 61000-4-2
Switching times 1 μs - 5 μs
Test duration 300 ms ±10%
Uvar with step transformer 50 - 277 VAC, 50/60 Hz