3-Phase Coupling / Decoupling Networks (CDN's)

(Showing 12 of 13)

3-Phase Coupling/Decoupling Networks (CDN's)

Show 12
  • Haefely

    SKU: sku-444

    Haefely PCD 130 3 Phase Coupling/Decoupling Network for PSURGE 8000

    Weight: 69 kg (net weight)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Coupling: 3 Phase - 32 Amps, 690 VAC
    Dimensions: 45 x 50 x 57 cm (W x H x D)
    General Data: Technical Details
    Phase synchronization: 1° steps
    Polarity: pos / neg
    Pulse current (short circuit): 32A RMS
    Pulse voltage (open circuit): 690V RMS (Phase-Phase) 110V DC
    Standards Met: IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45
  • Teseq

    SKU: sku-221

    Teseq CDN 3083-Burst 1000 Volt, 100-200 Amp Coupler for EFT/Burst

    Weight: 11 kg (24 lbs)
    Application/Test Type: EFT/Burst testing of equipment requiring large currents, specially designed for heavy industry, smart grid and electro vehicle applications.
    Current Rating: 100 Amp or 200 Amp continous depending on model
    Dimensions: 430 x 310 x 190 mm
    Mains & EUT Connections: SHV; Screw terminals, rated for 200 A
    Standards Met: IEC / EN 61000-4-4 up to 8.8 kV
    Voltage Rating: 690 V AC RMS; 1000 VDC
  • Teseq

    SKU: sku-220

    Teseq CDN 3083-Surge 620 Volt, 100-200 Amp Manual Coupler

    Weight: 80 kg (176 LB's)
    Application/Test Type: Manual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
    Current Rating: 100 Amp or 200 Amp continous depending on model
    Dimensions: 850 x 520 x 345 mm
    Mains & EUT Connections: Fischer 105 series; Screw terminals, rated for 230 A
    RF Input Voltage: Max. 8 kV / 4 kA
    Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
    Voltage Rating: 620 VAC RMS L-to-L (max. 440 V for NSG 3040 and Modula); 620 VAC RMS L-to-PE (max. 440 V for NSG 3040 and Modula); 620 VDC
  • Teseq

    SKU: sku-219

    Teseq CDN 3063-S100 Automated Surge CDN Coupler - 3 Phase, 100 Amp, 480 Volts

    Weight: 100 kg (220.5 lb)
    Application/Test Type: Automated Surge Testing for EUT up to 100 Amps, 480 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
    Current Rating: 3 x 100 Amp continuous (peak 3 x 150 Amp for 30 min.)
    Dimensions: 570 x 840 x 630mm (22.4 x 33 x 24.8")
    Frequency Range: DC – 65 Hz with no loss, 400 Hz max. with power loss
    Mains & EUT Connections: HV-surge pulse input from generator (Fischer connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)
    Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
    Voltage Rating: EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range, up to 225 VDC – up to 7 A
  • Teseq

    SKU: sku-218

    Teseq CDN 3063-S63 3 Phase, 63 Amp Automated Surge CDN Coupler for NSG 3040/3060

    Weight: 100 kg (220.5 lb)
    Application/Test Type: Automated Surge Testing for EUT up to 63 Amps, 480 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
    Current Rating: 3 x 63 Amp continuous (peak 3 x 100 Amp for 30 min.)
    Dimensions: 570 x 840 x 630mm (22.4 x 33 x 24.8")
    Frequency Range: DC – 65 Hz with no loss, 400 Hz max. with power loss
    Mains & EUT Connections: HV-surge pulse input from generator (Fischer connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)
    Standards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
    Voltage Rating: EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range, up to 225 VDC – up to 7 A
  • Teseq

    SKU: sku-84

    Teseq CDN 3063-X32 3 Phase, 32 Amp CDN Coupler for NSG 3040/NSG 3060

    Weight: 42 kg (96.6 lb)
    Application/Test Type: Automated Surge Testing for EUT up to 32 Amps, 480 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
    Current Rating: 3 x 32 Amp continuous (peak 3 x 50 Amp for 10 min.)
    Dimensions: W: 449 mm (17.7") x H: 310.5 mm (12.25"), 7 HU x D: 565 mm (22.2")
    Mains & EUT Connections: HV-surge pulse input from generator (Fischer connector); EFT input connector from generator (SHV connector); Connector for EUT supply input (Screw terminals Phoenix); Connector for EUT supply output (Screw terminals)
    Standards Met: IEC / EN 61000-4-4 Ed. 2:2004., IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
    Voltage Rating: EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range, up to 225 VDC – up to 7 A