CISPR 15 Test Equipment, Systems & Solutions
-
Teseq CDN M532 5-Line/32 Amp RF Coupling/Decoupling Network
SKU: sku-2093
Weight: 6.5 kgCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dB -
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: sku-827
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00Typically In Stock -
Dressler T4 CDN for Unshielded Symmetrical Telecom Lines 150 kHz-230 MHz
SKU: sku-401
Weight: 2.3 Lbs (1.04 kg)Application/Test Type: For CDN disturbing signals to an unscreened cable with balanced linesCurrent Rating: 2 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-399
Weight: 1.9 Lbs (0.86 kg)Application/Test Type: For coupling and decoupling of interference signals on screened linesCurrent Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Dressler AF4 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-398
Weight: 3.3 Lbs (1.5 kg)Current Rating: 2 AmpsFrequency Range: 150 kHz to 230 MHzRF Connector: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
EM Test (Lüthi) CDN T-Type Coupling/Decoupling Network for Unshielded Lines
SKU: sku-232
Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCurrent Rating: 1.5 Amps (3/5 Amp models available)Frequency Range: 150 kHz to 230 MHz (limited to 80 MHz on 3/5 Amp models)Mains & EUT Connections: Banana, XLR, RJ45, RJ11RF Connector: BNC, 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s -
EM Test (Lüthi) AF-Type Coupling/Decoupling Network for Unscreened/Unsymmetrical Lines
SKU: sku-231
Application/Test Type: Immunity test to conducted disturbances, induced by radio-frequency fields according to the standardsCurrent Rating: 1.5 Amps (Optional 3 Amps)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHzMains & EUT Connections: 4 mm banana or D-Sub 15/25 pinsRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6, CISPR 15, IEC/EN 60945, EN 55015Voltage Rating: AC max. voltage (line to ground): 63V - 250V; DC max. voltage (line to ground): 100V - 250V; -
Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines
SKU: sku-230
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low currentCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 ΩCurrent Rating: 200 mA to 4 Amps (refer to data sheet for exact model specifications)Decoupling of Common Mode Disturbance: 10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHzMains & EUT Connections: 4 mm banana or D-Sub 25 pinsRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6, CISPR 15Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB, 10 dB ±1 dB for CDN A501, A701, A801; 80 MHz to 300 MHz 1): 9.5 dB +3 dB / -2 dB 10 dB +3 dB / -2 dB for CDN A501, A701, A801; All other models 10 dB ±1 dBVoltage Rating: AC max. voltage (line to ground): 63V - 160V; DC max. voltage (line to ground): 100V - 250V; Test voltage: 250 V - 400 V DC, 2 sec (refer to data sheet for exact model specifications) -
Teseq CDN T Series Coupling Network for Unscreened Communication/Data Lines
SKU: sku-228
Weight: 0.5 kg (1.1 LB.'s)Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCommon Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω; 80 MHz to (230) 300 MHz: 150 Ω +60 Ω / -60 ΩCurrent Rating: 400 mA (line), 800 mA (pair)Decoupling of Common Mode Disturbance: 10 kHz: Over 20 dB; 1.5 MHz / 30 MHz: Over 55 dB; 80 MHz: Over 45 dB; 230 MHz: Over 35 dB;Dimensions: 4.1 x 2.5 x 4.3 inches (10.5 cm x 6.5 cm x 11.0 cm)Frequency Range: 150 kHz to 80 MHz (Optional 10 kHz - 230/300 MHz)Mains & EUT Connections: D-Sub adapter to RJ45 / RJ11 (1 mm banana on certain 10 kHz models)RF Connector: BNC, 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6Voltage Division Factor: 9.5 dB ±1 dB (10 kHz to 230 MHz: 10 dB ±1 dB)Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s -
Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps
SKU: sku-227
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M432 32 Amp Coupling/Dcoupling Network
SKU: sku-226
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M416 4-Line Coupling/Decoupling Network
SKU: sku-225
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec