Overview
Schwarzbeck HHS 5215-100 Helmholtz Coils.
Schwarzbeck HHS 5215-100 Specifications | |
Number of turns (per coil) | 100 |
Maximum Coil Current | 20 A, 5 min. |
Nominal Coil Current | 10 A continuous |
Maximum Magnetic Field Strength | ca. 2000 A/m |
Nominal Magnetic Field Strength | max. 5 min., dist. 0.6 m* |
Magnetic Fieldstrength, 1 A Coil Current | 842 A/m continuous |
Current required for 10 A/m | 0.84 m* |
Magnetic field strength caused by 1 A coil current (coil factor) | 84.2 A/m (Coil dist. 0.84 m*) |
Current required for 100 A/m at best possible homogeneity | 1.19 A (Coil dist. 0.84 m*) |
Outer mechanical dimensions | 1.69 m x 1.60 m x 1.00 m |
Average electrical side length | 1.533 m |
Maximum coil separation | 0.93 m* |
Usable frequency range | 0 - 6 kHz |
Inductance (per coil) | 52 mH |
Inductance (Pair of coils) | 112 mH |
Resistance (Pair of coils) | 9 ? |
Resonant frequency (Pair of coils) | > 20 kHz |
Weight | 53 kg |