Amplifier Research PM2003 Power Meter, 3 Channel, 10 kHz - 40 GHz, -70dBm to +44dBm
SKU: sku-805
Weight: 7 lbs (3.2 kg)Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deepRF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependentRF Field Probe Maximum Input Power: May be operated into 1kW or 1V fsRF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent -
Keysight / Agilent E9304A RF Power Sensor, 9 kHz - 6 GHz
SKU: 6577
Frequency Range: 9 kHz to 6 GHzApplication: Radiated ImmunitySensitivity: -60 to +20 dBmConnector: Type-NIn Stock -
Rohde & Schwarz (R&S) NRP-Z55 Thermal Power Sensor
SKU: sku-714
RF Field Probe Connector: 2.92 mm connectorRF Field Probe Frequency Range: DC to 44 GHzRF Field Probe Maximum Input Power: 10 W (PK, 1 µs)RF Field Probe Measurement Accuracy: Measurement range: –35 dBm to +20 dBmSupply Voltage: Operation with R&S®NRP2 base unit or via USB on a Laptop/PC$295.00 -
Used Amplifier Research PM2002 10 kHz - 40 GHz, -70dBm to +44dBm Power Meter
SKU: sku-706
Weight: 7 lbs (3.2 kg)Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deepRF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependentRF Field Probe Maximum Input Power: May be operated into 1kW or 1V fsRF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent -
Rohde & Schwarz NRP6A Average Power Sensor, 8 kHz - 6 GHz
SKU: sku-679
Frequency Range: 8 kHz to 6 GHzRF Power Range: 100 pW to 200 mW (–70 dBm to +23 dBm)Max Average Power: 1 WattPeak Envelope Power: 2 Watts for 10 µs (then Kaploowee) -
Rohde & Schwarz NRP2 RF Power Meter
SKU: 1845-1
$395.00In stock -
Teseq PMU 6003 USB Power Meter/Sensor 9 kHz - 3 GHz
SKU: sku-606
Current rating: 100 mA at 5 VFrequency Range: 9 kHz – 3 GHzRF Connector: N male 50 ΩStandards Met: IEC/EN 61000-4-3 IEC/EN 61000-4-6Supply Voltage: min. 4.7 V / max. 9 V -
PMM (Narda) 6630 USB RF Power Sensor 9 KHz - 3 GHz, 1 W
SKU: sku-470
Weight: 0.12 kgDimensions: 30 x 30 x 95 mmGeneral Data: Technical DetailsRF Field Probe Connector: N male, 50 ΩRF Field Probe Frequency Range: 9 kHz to 3 GHzRF Field Probe Max SWR: 10 kHz to 300 kHz 1,10 from +30 dBm to -9 dBm 300 kHz to 100 MHz 1,05 100 MHz to 1 GHz 1,10 1 GHz to 3 GHz 1,25 10 kHz to 3 GHz 1,20 from -9 dBm to -40 dBmRF Field Probe Maximum Input Power: 2 W peak envelope max 300 msRF Field Probe Measurement Accuracy: less than 0,35 dBRF Field Probe Power Linearity: -40 dBm to +30 dBm @ 50 MHz 0,2 dBRF Field Probe Power Measurement Range: 100 nW to 1 W (-40 dBm to +30 dBm)RF Field Probes: Power SensorSupply Voltage: 5 Volt DC – 100 mA (from USB Port) -
Boonton 5008 USB Peak Power Sensor 50 MHz- 8 GHz
SKU: 5150
Frequency Range: 50 MHz to 8 GHzDynamic Range (Average): -60 to +20 dBmDynamic Range (Pulse): -50 to +20 dBmRise time (fast/std): 4 ns / < 10 µsSingle-shot Bandwidth: 35 MHzVSWR: 1.20 (0.05 to 6 GHz), 1.25 (6 GHz to 8 GHz)Applications: Radiated Immunity, RF Conducted ImmunityIn Stock -
Teseq ITS 6006 Radiated Immunity Test System
SKU: 11290
Frequency Range: 80 MHz to 6 GHzInput: External AM input: BNC socket, impedance more than 10 kΩ External PM input: BNC socket, TTLOutput: Generator outputs: 4x N sockets 50 Ω, 80 MHz to 6 GHz Interlock outputs: 4x BNC sockets External PM output: BNC socket, TTL, impedance more than 1.2 kΩ 10 MHz reference output: BNC socket, approx. 0 dBm/50 ΩReference frequency: 10 MHzApplications: RF/Radiated Immunity & Susceptibility Testing$18,000.00In Stock