Com-Power LISN's

(Showing 12 of 30)

LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.

Show 12 24

Com-Power LISN's Test Equipment, Systems & Solutions

  • Com-Power LI-215A 9 kHz - 30 MHz LISN w/ NEMA 5-15R Power Output Port

    SKU: sku-16

    Weight: 25 lbs. / 11.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cm
    Frequency Range: 9 kHz - 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Com-Power LIN-120A LISN for CISPR 16-1-2/ANSI C63.4 w/ built-in Transient Limiter

    SKU: sku-15

    Weight: 10 lbs (4.5 kg)
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 20 Amps AC (rms) , 14 Amps DC
    Dimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUT
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2, ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Com-Power LI-125A 150 kHz - 30 MHz LISN, 50 uH, 25 Amps (Discontinued)

    SKU: sku-12

    Weight: 25 lbs. / 11.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cm
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Com-Power LI-325C Line Impedance Stabilization Network

    SKU: 10891

    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7.5 x 8 inches / 33 x 19 x 20 cm
    Frequency Range: 10 kHz to 400 MHz
    Inductors: 5 µH (air-core)
    Insertion Loss: 0.3 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: RTCA DO-160, MIL-STD-461 LISNS
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
    Inquire for Availability
  • Com-Power LI-220C 9 kHz - 30 MHz LISN for CISPR 16-1-2/ANSI C63.4

    SKU: 10878

    Weight: 20.5 lbs / 9.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 20 Amperes AC, 14 Amperes DC
    Dimensions: 16.75 x 15.5 x 7.5 inches / 42.5 x 39.3 x 19 cm
    Frequency Range: 9 KHz - 30 MHz
    Inductors: 250 & 50 microhenry (air-core)
    Insertion Loss: 6 dB to 1 dB
    Isolation: 20 dB to 40 dB
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
    $295.00
    Typically In Stock
  • Com-Power LI-550C 100 kHz to 108 MHz LISN

    SKU: 8943

    Application/Test Type: Power line conducted emissions tests
    Current Rating: 50 Amps (AC), 35 Amps (DC)
    Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cm
    Frequency Range: 100 kHz to 108 MHz
    Inductors: 5 µH (air-core)
    Insertion Loss: 1.5 dB (150 kHz to 30 MHz)
    Isolation: 20 - 40 dB (100 kHz to 3 MHz) 40 dB ( 3 MHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 25, CISPR 16-1-2
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
    $30.00
    In Stock
  • Com-Power LI-3P-263 9kHz – 30MHz Three Phase LISN for CISPR / ANSI

    SKU: 11894

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current rating: 63 Amperes
    Dimensions: 19.3” x 13.9” x 2.3″
    Frequency Range: 9 kHz – 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω – N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Typically In Stock
  • Com-Power LI-350 Line Impedance Stabilization Network

    SKU: 10425

    Weight: 6 lbs. / 2.7 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 50 Ampere AC, 35 Ampere DC
    Dimensions: 15.4 x 7 x 6.6 inches / 39.1 x 17.7 x 16.7 cm
    Frequency Range: 10 kHz to 400 MHz
    Inductors: 5 µH (air-core)
    Insertion Loss: 0.2 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: RTCA DO-160 / MIL-STD 461F
    Voltage Rating: 480 VAC (Line to Ground), 676 VDC
    Inquire for Availability
  • Com-Power LI-325 10 kHz - 400 MHz LISN for RTCA DO-160 / MIL-STD 461D

    SKU: 10018

    Weight: 5 lbs. / 2.2 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7.5 x 8 inches / 33 x 19 x 20 cm
    Frequency Range: 10 kHz to 400 MHz
    Inductors: 5 µH (air-core)
    Insertion Loss: 0.3 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: RTCA DO-160, MIL-STD-461 LISNS
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
    Inquire for Availability
  • Rent Com-Power LI-3P-132 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network

    SKU: 11124

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 32 Amperes
    Dimensions: 19.3” x 13.9” x 2.3"
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    Inquire for Availability
  • Com-Power LI-3P-200 Series 3-Phase LISN's with 50/250 uH Inductor, FCC/EN/CISPR, up to 100 A, 150 kHz - 30 MHz

    SKU: sku-603

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: up to 100 Amperes
    Dimensions: 19.3” x 13.9” x 2.3"
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 µH or 250 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V