DEF STAN 59-411

Table 1 – Emission Tests
Commercial Test Title (examples) Def Stan 59-411 Test Title
EN 55022/11 Class A/B, EN 55014-1, EN 55015, EN 60945 Conducted disturbance mains port 9 kHz – 30 MHz DCE01 Power line conducted emissions 20Hz – 150MHz
EN 55022, Conducted common mode disturbance telecommunication port 150kHz – 30MHz DCE02 Signal, control and secondary power line conducted emissions 20Hz – 150MHz
EN 55022/11 Class A/B, EN 60945 Radiated disturbance 150kHz – 2GHz DRE01/DRE03 Electric field radiated emission 10kHz – 18GHz
EN 55011, EN 55015 Magnetic field strength 9kHz – 30MHz DRE02 Magnetic field radiated emission 20Hz – 100kHz
Table 2 – Susceptibility Tests
Commercial Test Title (examples) Def Stan 59-411 Test Title
EN 61000-4-16 Immunity to conducted, common mode disturbances 15Hz – 150kHz DCS01 Power line conducted susceptibility 20Hz – 50kHz
EN 61000-6-1 / EN 61000-6-2 Residential/Industrial limits, EN 61000-4-6 Immunity to conducted disturbances induced by radiofrequency fields 150kHz – 80MHz DCS02 Power and signal line conducted susceptibility 50kHz – 400MHz
EN 61000-4-16 Immunity to conducted, common mode disturbances 15Hz – 150kHz DCS03 Signal line conducted susceptibility 20Hz – 50kHz
EN 61000-6-1 / EN 61000-6-2 Residential/Industrial limits, EN 55024, EN 61000-4-8 Power frequency magnetic field immunity test 50Hz, 60Hz DRS01 Magnetic field radiated susceptibility 20Hz – 100kHz
EN 61000-6-1 / EN 61000-6-2 Residential/Industrial limits, EN 61000-4-3 Radiated, RF, electromagnetic field immunity test 80MHz – 2700MHz DRS02 Electric field radiated susceptibility 10kHz – 18GHz
EN 61000-4-8 Power frequency magnetic field immunity test, DC DRS03 DC magnetostatic field radiated susceptibility