| Table 1 – Emission Tests | |
|---|---|
| Commercial Test Title (examples) | Def Stan 59-411 Test Title |
| EN 55022/11 Class A/B, EN 55014-1, EN 55015, EN 60945 Conducted disturbance mains port 9 kHz – 30 MHz | DCE01 Power line conducted emissions 20Hz – 150MHz |
| EN 55022, Conducted common mode disturbance telecommunication port 150kHz – 30MHz | DCE02 Signal, control and secondary power line conducted emissions 20Hz – 150MHz |
| EN 55022/11 Class A/B, EN 60945 Radiated disturbance 150kHz – 2GHz | DRE01/DRE03 Electric field radiated emission 10kHz – 18GHz |
| EN 55011, EN 55015 Magnetic field strength 9kHz – 30MHz | DRE02 Magnetic field radiated emission 20Hz – 100kHz |
| Table 2 – Susceptibility Tests | |
|---|---|
| Commercial Test Title (examples) | Def Stan 59-411 Test Title |
| EN 61000-4-16 Immunity to conducted, common mode disturbances 15Hz – 150kHz | DCS01 Power line conducted susceptibility 20Hz – 50kHz |
| EN 61000-6-1 / EN 61000-6-2 Residential/Industrial limits, EN 61000-4-6 Immunity to conducted disturbances induced by radiofrequency fields 150kHz – 80MHz | DCS02 Power and signal line conducted susceptibility 50kHz – 400MHz |
| EN 61000-4-16 Immunity to conducted, common mode disturbances 15Hz – 150kHz | DCS03 Signal line conducted susceptibility 20Hz – 50kHz |
| EN 61000-6-1 / EN 61000-6-2 Residential/Industrial limits, EN 55024, EN 61000-4-8 Power frequency magnetic field immunity test 50Hz, 60Hz | DRS01 Magnetic field radiated susceptibility 20Hz – 100kHz |
| EN 61000-6-1 / EN 61000-6-2 Residential/Industrial limits, EN 61000-4-3 Radiated, RF, electromagnetic field immunity test 80MHz – 2700MHz | DRS02 Electric field radiated susceptibility 10kHz – 18GHz |
| EN 61000-4-8 Power frequency magnetic field immunity test, DC | DRS03 DC magnetostatic field radiated susceptibility |