Surge Generators

 

Surge immunity testing · IEC 61000-4-5

Everything you need for a complete surge test

A surge test is more than a generator. To run IEC 61000-4-5 correctly you need the generator, a coupling/decoupling network for every power and data port, and a way to prove the waveform is right. We rent and sell all of it, and we can ship a matched setup the same day.

  • Rentals ship same day
  • ISO 17025 calibrations available
  • Rent or buy
  • Matched generator + CDN sets

Your surge test checklist

  1. Surge generator (combination wave or telecom)
  2. Power-line CDN for AC/DC mains ports
  3. Data-line CDN for signal, comms and telecom ports
  4. Waveform verification: scope, HV probe, current monitor

How it fits together

The four parts of a surge test setup

1

Surge generator

Produces the combination-wave or telecom surge at the required level and phase angle.

2

Power-line CDN

Couples the surge onto AC/DC power lines and blocks it from the mains supply.

3

Data-line CDN

Couples onto signal, comms and telecom lines without loading the data.

4

Waveform verification

Confirms open-circuit voltage and short-circuit current meet tolerance.

Step 1

Surge generator

The generator sets your waveform, peak voltage and current, polarity and phase synchronization. Most IEC 61000-4-5 work uses a combination wave generator; telecom ports leaving the building call for 10/700 µs.

What to spec
  • Maximum voltage: 4 kV covers IEC levels 1–4; higher for UL 1449 or utility work
  • Waveform: 1.2/50 µs & 8/20 µs, plus 10/700 µs if you test telecom ports
  • Built-in CDN rating (single vs. three phase, max current) or external CDN
  • Multi-function units also cover EFT/burst and dips & interruptions
Surge4-5 Combination Wave Surge Generator
Combination waveSurge4-5 Combination Wave Surge GeneratorDedicated IEC 61000-4-5 surge with built-in single-phase coupling.View rental options →
EM Test NX5 Compact EMC Generator
Multi-functionEM Test NX5 CompactSurge, EFT/burst and power fail in one compact system.View rental options →
Thermo Keytek EMCPro Plus
Multi-function · 6 kVThermo Keytek EMCPro PlusSurge, EFT and dips with headroom above the 4 kV IEC level.View rental options →
EM Test TSS 500N6B Telecom Surge Simulator
Telecom · 10/700 µsEM Test TSS 500N6B Telecom Surge SimulatorTelecom surges for ITU-T K-series and GR-1089 ports.View rental options →

Combination wave Telecom surge Ring wave Damped oscillatory Lightning surge

Step 2

Coupling/decoupling network for power lines

The power-line CDN injects the surge onto the EUT's AC or DC supply while its decoupling side keeps the surge out of the mains and protects the supply. Use the generator's built-in CDN, or add an external one when you need three phase or more current.

What to spec
  • Phases and conductors: single phase (L, N, PE) or three phase (L1–L3, N, PE)
  • EUT rated voltage and current per line
  • Coupling paths: line-to-line (18 µF) and line-to-earth (10 Ω + 9 µF)
  • Generator compatibility: matching connectors and remote control
Haefely PCD 100 Single Phase CDN
Single phaseHaefely PCD 100 Single Phase CDNSingle-phase coupling for the PSURGE 8000 platform.View rental options →
Teseq CDN 3083-Surge
3 phase · 100–200 ATeseq CDN 3083-Surge620 V, 100–200 A manual coupler for high-current EUTs.View rental options →
3cTest SEPN 38100T 3 Phase Coupling Network
3 phase · surge + EFT3cTest SEPN 38100TThree-phase surge and EFT coupling network.View rental options →
KeyTek CM-3CD-32 3 Phase Coupler/Decoupler
3 phase · 32 AKeyTek CM-3CD-32Three-phase surge coupler/decoupler.View rental options →

All 3-phase surge CDNs All CDNs

Step 3

Coupling/decoupling networks for data lines

Signal, control and communication ports need their own CDN. It couples the surge onto the lines through a series resistance (40 Ω for 1.2/50 µs) using capacitors or gas arresters. Its decoupling side isolates the auxiliary equipment while still passing the data.

What to spec
  • Line type: unshielded unsymmetrical (RS-485, CAN, I/O), symmetrical twisted pair, or shielded
  • Number of lines and pairs to couple (2, 4, 8-wire)
  • Data rate: high-speed lines such as Ethernet need a low-loss CDN
  • Waveform: 1.2/50 µs in-building, 10/700 µs for outdoor telecom lines
Teseq CDN 118-T4
Twisted pair · 1.2/50 & 10/700Teseq CDN 118-T4CDN set for 1 or 2 twisted pairs, both waveforms.View rental options →
EM Test CN 508S1 Surge CDN for Data Lines
Signal & control linesEM Test CN 508S1Surge CDN for data and control lines.View rental options →
Teseq CDN HSS-2
High-speedTeseq CDN HSS-2Surge coupling for high-speed communication lines.View rental options →
3ctest CDN 405T8
8-wire · high-speed3ctest CDN 405T8Surge coupler for high-speed 8-wire data lines.View rental options →

All data-line & telecom surge CDNs

Step 4

Waveform verification tools

IEC 61000-4-5 requires the surge waveform to be verified at the generator output and at the CDN's EUT port. That means measuring open-circuit voltage with a high-voltage probe, then short-circuit current with a current monitor, on an oscilloscope.

What you're checking
  • Open-circuit voltage: 1.2 µs front time (±30%), 50 µs duration (±20%)
  • Short-circuit current: 8 µs front time (±20%), 20 µs duration (±20%)
  • Peak values at each test level, both polarities
  • Repeat at the CDN output for each coupling path
ECO500M 500 MHz Oscilloscope
OscilloscopeECO500M 500 MHz OscilloscopePre-programmed for transient waveform measurements.View rental options →
DP7 High Voltage Probe
Voltage · VocDP7 High Voltage ProbeMeasures the open-circuit 1.2/50 µs voltage waveform.View rental options →
Pearson 411 Surge Current Monitor
Current · IscPearson 411 Surge Current MonitorUp to 5 kA peak for the 8/20 µs short-circuit current.View rental options →

All waveform verification equipment

Reference

Surge waveforms & test levels

Waveform Open-circuit voltage Short-circuit current Typical use
Combination wave 1.2/50 µs 8/20 µs Power & in-building signal ports
Telecom wave 10/700 µs 5/320 µs Outdoor symmetrical telecom lines

The combination wave generator has a 2 Ω effective output impedance, so peak short-circuit current is half the open-circuit voltage.

IEC level Open-circuit voltage Short-circuit current
1 0.5 kV 0.25 kA
2 1 kV 0.5 kA
3 2 kV 1 kA
4 4 kV 2 kA

Generator output, with no EUT connected. Level X is set by the product standard.

Standards

Surge immunity standards we support

Surge generators can also drive magnetic field coils for IEC 61000-4-8 and IEC 61000-4-9 pulsed magnetic field testing.

Get a complete, matched surge setup

Tell us your EUT's ports, voltage and current. We'll pair the generator, CDNs and verification kit, and ship rentals the same day.