Impedance Stabilization Networks (Power and Dat...

(Showing 12 of 53)

Impedance Stabilization Networks  also known as Artificial Mains Networks are the most common transducer to perform conducted emission testing. For testing electrical power lines a Line Impedance Stabilization Network (LISN) is required. To test data lines an Impedance StabilizatioN Network (ISN) is used.

Show 12 24 36 48

Impedance Stabilization Networks (Power and Dat... Test Equipment, Systems & Solutions

  • PMM L3-500 500 Amp, 9 kHz - 30 MHz Line Impedance Stabilization Network (LISN)

    SKU: sku-62

    Weight: 248 kg (546 pounds)
    Application/Test Type: LISN for AC Three phase plus neutral V-Network power circuits
    Current Rating: 300 Amps continuous (500 Amps for 20 minutes)
    Dimensions: 555 x 930 x 830 mm (21 x 36.6 x 32.6 inches)
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 Ω // [5 Ω + 50 µH] with 250 µH Choke or Bypass
    Input: 230 V - 50/60 Hz, 50 VA each line
    Mains & EUT Connections: M14 bolts
    RF Connector: BNC (f)
    RF Input Voltage: BNC (f)
    Standards Met: CISPR 16-1-2; VDE 0876; FCC part 15; MIL-STD 461F
  • Com-Power LI-1100C Line Impedance Stabilization Network 150 kHz to 30 MHz

    SKU: sku-17

    Weight: 17 lbs. / 7.7 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 100 Amps (AC), 70 Amps (DC)
    Dimensions: 10 x 10 x 21 inches /25.4 x 25.4 x 53.3 cm
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets - Input: 120 VAC 60Hz, Output: 12 VDC 1 Amperes (Fan Power Adapter)
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 440 VAC (Line to Ground), 620 VDC
    $5,665.00
  • Com-Power LI-215A 9 kHz - 30 MHz LISN w/ NEMA 5-15R Power Output Port

    SKU: sku-16

    Weight: 25 lbs. / 11.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cm
    Frequency Range: 9 kHz - 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Com-Power LIN-120A LISN for CISPR 16-1-2/ANSI C63.4 w/ built-in Transient Limiter

    SKU: sku-15

    Weight: 10 lbs (4.5 kg)
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 20 Amps AC (rms) , 14 Amps DC
    Dimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUT
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2, ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Com-Power LI-125A 150 kHz - 30 MHz LISN, 50 uH, 25 Amps (Discontinued)

    SKU: sku-12

    Weight: 25 lbs. / 11.3 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cm
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH (air-core)
    Insertion Loss: 0.5 dB (150 kHz to 30 MHz)
    Isolation: 40 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2 / ANSI C63.4
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
  • Schwarzbeck NNLK 8121 100 Amp Line Impedance Stabilization Network

    SKU: 10857

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 100 Amperes
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Frequency Range: 9 kHz - 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    Typically In Stock
  • EMCO (ETS-Lindgren) 3810-2 LISN, NEMA, 9 kHz - 30 MHz, 10 Amps

    SKU: 11287

    Weight: 10.7 lbs. / 4.9 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 10 Amps
    Dimensions: 8.7 x 15 x 6 inches / 22.2 x 38.1 x 15.2 cm
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 µH/250µH
    Mains & EUT Connections: NEMA typical. (SCHUKO and British available upon request)
    RF Connector: 50Ω BNC Monitor
    Standards Met: FCC 15, VDE 0871, VDE 0875
    Voltage Rating: 250 VAC (Line to Ground)
    $195.00
    In Stock
  • LISN-CISPR16-32A Line Impedance Stabilization Network

    SKU: 6054

    EUT Current Handling: 32 Amps
    Line Voltage: It can be operated with any supply voltage which does not exceed 540V/260V, 50Hz/60Hz. It is also suitable for DC operation.
    Services Available: ISO 17025 Calibration, Rentals, Leases, Purchases, Repairs, Eval/Characterization
    Test Standards: CISPR 16-1-2, VDE 0876, FCC part 15, MIL-STD 461, ISO 60601-1-2
    Inductance: 50 uH
    $3,950.00
    In Stock
  • Com-Power LI-325C Line Impedance Stabilization Network

    SKU: 10891

    Weight: 5 lbs. / 2.2 kg
    Application/Test Type: Power line conducted emissions tests
    Current Rating: 25 Amps (AC), 17 Amps (DC)
    Dimensions: 13 x 7.5 x 8 inches / 33 x 19 x 20 cm
    Frequency Range: 10 kHz to 400 MHz
    Inductors: 5 µH (air-core)
    Insertion Loss: 0.3 dB (150 kHz to 30 MHz)
    Mains & EUT Connections: Superior Electric SUPERCON® shrouded sockets
    RF Connector: 50Ω N-type (female)
    Standards Met: RTCA DO-160 / MIL-STD 461D
    Voltage Rating: 270 VAC (Line to Ground), 380 VDC
    Inquire for Availability
  • Com-Power ISN-T8 Impendace Stabilization Network and Calibration Kit

    SKU: sku-1131

    Weight: 1.4 lbs. (0.6 kg) [ISN + LCL Adapter + Connecting Adapter]
    Current Rating: 800 mA (per line), 1.6 Amps (per pair)
    Dimensions: see photo in images
    Frequency Range: 150 kHz to 30 MHz
    Isolation: 150 kHz to 1.5 MHz: 35 to 55 dB 1.5 MHz to 30 MHz: 55 dB
    Mains & EUT Connections: D-sub 25 pin female connectors
    RF Connector: 50Ω N-type (female)
    Standards Met: CISPR 16-1-2, CISPR 22/32
    Voltage Rating: 50 VDC / 32 VAC (line to ground @ 50/60 Hz)

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.