E-Field Probes up to 10 GHz Test Equipment, Systems & Solutions
-
Lumiloop LSProbe 1.2 Laser Powered Field Probe for CW and Pulse Testing
SKU: 7384
Application/Test Type: Radiated ImmunityField Strength Range: 0.1 V/m to 1,000 V/m (7 to 10 kV/m under 30 MHz)Frequency Range: 10 Hz to 8.2 GHzResolution: <0.01 V/mTest Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20Typically In Stock -
Amplifier Research PL7004 800MHz - 3.6GHz Electric Field Pulse Laser Powered Probe
SKU: 11935
Amplitude Accuracy: Without correction factors applied: ±1.5 dB @ 1 GHz; With correction factors applied: Typical expanded measurement uncertainty (95% confidence interval), 0.8 dB, 800 MHz–1 GHz; 1.4 dB, 1GHz–3.6 GHzCalibration Data: Accredited Calibration Report supplied with probeDamage Level: 1000 V/m, Continuous Field or Pulsed FieldFiber Optic Connectors: Two E2000 Compact Duplex Connectors at 1 Meter, Includes Fiber Optic Verification Loop.Frequency Range: 800MHz - 3.6GHzIsotropic Deviation: ±1.0 dB @ 1 GHz. For improved accuracy, this probe should be used with a single axis aligned with the E-field being measured.Measurement Data Processing: The pulse amplitude measurement is smoothed before being sampled and digitized. The smoothing process has a time constant of 300 msec.Operating Range: 80–800 V/mPulse Duration: 0.02% to 2%Pulse Measurement Variation: Over Range of Pulse Width, Period, and Duty relative to a 10 microsecond pulse width and 1 millisecond pulse period (1kHz pulse rate, 1% duty): ±0.5 dB/–1.0 dB typicalPulse Period: Up to 5 milliseconds between pulses (greater than 200 Hz pulse rate)Pulse Width: 1 to 100 MicrosecondsRelative Flatness: ±2.5 dB, 800 MHz-3 GHz; ±3.0 dB, 3.0GHz 3.6GHzTemperature Stability: +0.5 dB Over Operating Temperature Range -
Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe
SKU: 11934
Weight: 62.5 g (2.2 oz)Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Analog Response Time: 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfacesCalibration Data: Accredited Calibration Report (A2LA) supplied with probeDamage Level: 1000 V/m continuous fieldData Returned From Probe: X, Y, Z axes, and CompositeDimensions: 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axesFiber Optic Connectors: Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.Isotropic Deviation: ± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)Linearity: ± 0.5 dB and ± 0.9 V/mOperating Range: 1.5–300 V/mOperating Temperature: 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensingPower Requirements: Laser powered from FI7000 interfaceRise time: Typical Analog 300nSTemperature Stability: ± 0.5 dB over operating temperature range -
Amplifier Research FA7006 6 GHz E-Field Probe Kit
SKU: 11933
Test Standards: IEC 61000-4-3Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Damage Level: 1000 V/mDimensions: 5.7 x 5.7 x 5.7cmLinearity: ±0.5dBMinimum Pulse Width: 2μsOperating Range: 9 – 900V/mRise time: Typical Analog 300nSTemperature Stability: ±1.0dB, 10°C - 40°C8Typically In Stock -
Narda PMM EP-602 5 kHz - 9.25 GHz Broadband Active Electric Field Probe
SKU: 5497
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 1.5 to 1500 V/m (0.01 V/m)Frequency Range: 5 kHz to 9.25 GHzStandard Met: IEC/EN 61000-4-3Interface: Fiber-OpticBattery Life: 60-80 hoursDynamic Range: 1,5 to 1500 V/m, 60 dB single rangeTypically In Stock -
Narda PMM EP-601 10 kHz – 9.25 GHz Broadband Active Electric Field Probe
SKU: 5271
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 0.5 to 500 V/m (0.01 V/m)Frequency Range: 10 kHz to 9.25 GHzStandards Met: IEC/EN 61000-4-3Interfaces: Fiber-OpticBattery Life: 60-80 hoursInquire for Availability -
Narda PMM EP-600 Isotropic E-Field Probe 100 kHz-9.25 GHz
SKU: 6347
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 0.14 to 140 V/m (0.01 V/m)Frequency Range: 100 kHz to 9.25 GHzStandards Met: IEC/EN 61000-4-3Interfaces: Fiber-OpticBattery Life: 60-80 hoursTypically In Stock -
Amplifier Research FP5000 Isotropic E-Field Probe, 10 kHz - 1 GHz
SKU: 4902
Frequency Range: 10 kHz - 1 GHzResponse Time: 40 msec. minimumIsotropicity: +/-0.5 dB on three orthogonal axesSensitivity: 1-300 V/MSampling Rate: 1-26 samples/secondApplications: Monitoring Electric Field StrengthsTest Standards: IEC/EN 61000-4-3$3,950.00In Stock -
Amplifier Research (AR) FL7006 Electric Field Probe Kit, 100 kHz - 6 GHz
SKU: 57543
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 0.5 to 800 V/m (0.01 V/m)Frequency Range: 100 kHz to 6 GHzStandards Met: IEC/EN 61000-4-3Interfaces: USB, IEEE-488 (GPIB), RS-232 (serial), Fiber-Optic SerialBattery Life: 60-80 hoursTypically In Stock