Telecom Testing Categories
Telecom Testing Test Equipment, Systems & Solutions
-
EM Test TSS 500N4B Telecom Surge Generator
SKU: 9122
Applications: Telecom Testing, Conducted ImmunityTest Standards: Bellcore/Telcordia GR-1089-CoreWaveform: 10/250usOutput Voltage: 100 Volts to 4,000 VoltsOutput Current: 50 Amps to 2,000 Amps$1,950.00In Stock -
EM Test TSS 500N6B Telecom Surge Simulator
SKU: 6885
Output Voltage: 100 - 5,000 VoltsOutput Current: 5 - 500 Amps per wireTest Standards: Bellcore/Telcordia GR-1089-CORE, ITU-T K.12, ITU-T K.28, ITU-T K.45Pulse Waveforms: 10/360µs, 10/1,000µs and 2/10µsTelecom Port Testing: 2-wire, 4-wire (up to 12 pair with CNB 500)$2,975.00In Stock -
Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6
SKU: 10828
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$1,190.00 -
Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68
SKU: sku-776
Weight: approx. 35kgApplication/Test Type: Test levels as per FCC part 68Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PEDimensions: 19“ / 6HU,Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)Outputs: 4 mm banana socketPolarity: pos / neg / alternateRise time: Less than 2 usTelecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)Trigger of bursts: Automatic pulse release -
EM Test CSS 500N10 Current Surge Generator, 8/20us Up To 10ka
SKU: 30061
Weight: approx. 66 lbs.Coupling: N/ADimensions: 19"/6HU,Polarity: positive / negative / alternatePulse current (short circuit): 0.4kA to 10kA +/-10%Pulse voltage (open circuit): 250V to 6,000V +/-10%, Step width 50VRepetition time: Max. 10 pulses per minute, depending on the charging voltageInquire for Availability -
EM Test TSS 500N10 Telecom Surge Generator ITU-T for Enhanced Level Testing up to 10 kV
SKU: sku-403
Weight: approx. 37.1 kg (81.8 lbs.)AC Power Adapter: Supply voltage 115/230 V +10/-15%Dimensions: 19"/9 HU, 420 mm x 448 mm x 500 mmEnergy Storage Capacitor: 1 uF (Pulse 1.2/50 us) 20 uF (Pulse 10/700 μs) 20 uF (Surge Pulse B)Front Time: 1 us ± 30% (Pulse 1.2/50 us) 10 us ± 30% (Pulse 10/700 μs) 9 us ± 30% (Surge Pulse B)Pulse Duration: 50 us ± 20% (Pulse 1.2/50 us) 700 us ± 20% (Pulse 10/700 us) 720 us ± 20% (Surge Pulse B)Standards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.21 ITU-T K.28 ITU-T K.45 (and more)Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 500 V - 10,000 V ± 10% -
EM Test TSS 500N4 Telecom Surge Generator as per ITU / FCC up to 4 kV
SKU: sku-402
Weight: approx. 20 kg (44 lbs.)AC Power Adapter: Supply voltage 115/230 V +10/-15%Dimensions: 19"/3HUStandards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.28 ITU-T K.45 (and more)Voltage Rating: 160 V - 4,000 V ±10% -
3ctest CWS 600 6kV Surge Simulator for IEC 61000-4-5
SKU: 11331
New Systems: Inquire to purchase a new unitStandards Met: UL 1449, IEC/EN 61000-4-5, IEC/ISO 60601-1-2Coupling: Single Phase Built in, 16A, 250VAC, 120VDCApplications: EMC Surge, CE MarkingMains & EUT Connections: 4mm banana plugPolarity: Positive, Negative, AlternatePulse current (short circuit): 0.1kA-3kA ±10%Pulse repetition: 1-999Pulse voltage (open circuit): 0.2kV - 6kV ±10%$1,490.00In stock -
3ctest GN MT6 Multifunctional Transient Immunity Generator
SKU: 10541
Standards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Applications: Conducted Immunity Testing, CE Marking, Medical DevicesMax EUT Voltage (w/ Built in CDN): 400 VoltsMax EUT Current (w/ Built in CDN): 20 AmpsPeak inrush current capability: 500 Amps (up to 2.5 kA)EFT/Burst Pulse Output Capability: 6 kVCombination/Wave Surge Output Capability: 6 kVTypically In Stock -
EM Test NX5 Compact EMC Generator for EFT/Burst, Surge & Power Fail
SKU: 10547
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Applications: Conducted Immunity Testing, CE Marking, Medical DevicesMax EUT Voltage (w/ Built in CDN): 300 VoltsMax EUT Current (w/ Built in CDN): 16 AmpsPeak inrush current capability: 500 Amps (up to 2.5 kA)EFT/Burst Pulse Output Capability: 5.5 kVCombination/Wave Surge Output Capability: 5 kVExternal Coupling: Data Lines (EFT & Surge), 3PH EUTDips, Interrupts & Variations: 16 Hz - 500 Hz and DC$2,195.00Typically In Stock -
EM Test VCS 500N10T Combination Wave Telecom Surge Generator
SKU: 10796
EMC Standards: IEC 61000-4-5, IEC 61000-4-9Pulse current (short circuit): max. 5,000A ± 10%Pulse voltage (open circuit): 500V - 10,000V ± 10%Test duration: 1 - 30,000 or endlessCoupling Network: EMTest CN 508S1In stock -
Teseq NSG 3060-ITU Transient Generator for Surge, Telecom, EFT/Burst, IEC and ITU-T.K
SKU: 10406
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage (w/ Built in CDN): 264 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 220 VoltsMax EUT DC Current (w/ Built in CDN): 10 AmpsPeak inrush current capability: 500 A (at 230 V)EFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps) - open circuit±100 V to 2.4 kV ±100 A to 2.2 kACombination/Wave Surge Output Capability: ±200 V to 4.4 kV (in 1 V steps)External Coupling: Data Lines (EFT & Surge), 3PH EUTCoupling: ANSI / IEC / externalPhase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)Polarity: positive / negative / alternateTest duration: 1 s to 1000 hBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 100 Hz to 1000 kHzBurst time: 1 μs to 1999 s, single pulse, continuousCombination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling-2: ANSI / IEC / externalImpedance: 2/12 ΩOutput Current: 5 to 500 APhase synchronization-2: asynchronous, synchronous 0 to 359º (in 1º steps)Polarity-2: positive / negative / alternatePulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit; ±100 V to 2.4 kV (50 Ω matching system)Pulse current (short circuit): ±100 A to 3.3 kAPulse repetition: 5* to 20 s, up to 600 s (in 1 s steps) * derated depending on selected pulse voltage and EUT supply voltagePulse voltage (open circuit): ±200 V to 6.6 kV (in 1 V steps)Repetition Rate: 10 to 600 sRepetition time: 1 ms to 4200 s (70 min)Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest duration-2: 1 to 9999 pulses, continuousTest Voltage: 200 to 7.7 kVTransfer Impedance: 15 and 40 ΩInquire for Availability