Used Pulse/Transient Generators Test Equipment, Systems & Solutions
-
Teseq NSG 3025 Fast Transient/EFT Generator for IEC/EN 61000-4-4
SKU: 11993
Test Capabilities: Electrical Fast Transient ImmunityStandards Met: IEC/EN 61000-4-4Applications: EMC Precompliance Testing, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage / Current (w/ Built in CDN): 250 Volts, 16 AmpsMax EUT DC Voltage / Current (w/ Built in CDN): 120 Volts, 16 AmpsEFT/Burst Pulse Output Capability: 4.8 kVExternal Coupling: Data LinesWas:$9,500.00$7,500.00In Stock -
RFCI-IEC-25 Conducted Disturbance Test Generator
SKU: 8021
Frequency Range: 100 kHz - 250 MHzPower: 25 WMeasuring range: +30 dBm to – 40 dBmOutput Connector (Amplifier Monitor): BNC, 50 Ω / -40 dB (amplifier output), ±3 dBTest Standards: IEC/EN 61000-4-6$1,195.00In Stock -
Solar 7054-1 Voltage Spike Generator
SKU: SO-7054-1-CL
Test Standards: MIL-STD-462 Figure 19Applications: EMI/EMC For Military Aircraft And AviationSpike Amplitude: 10 - 600 VoltsSpike Repetition Rate: 0.8 - 10 Pulses Per SecondSpike Rise Time: <1 microsecondCondition (Scale 5-10): 6-7$3,975.001 UNIT -
Schaffner NSG 2025-4 EFT / Burst Generator Built in Three Phase Coupler
SKU: 11294
Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1 kHz - 1,000 kHzBurst time: Rise Time: 5ns ±20% (50 W, 10 - 90%) Pulse Width: 50ns ±30% (50 W and 1 W), 100ns ±50% open circuitCoupling: Line to reference ground (IEC 1000-4-4), selected lines together to reference ground, all lines to reference ground (common mode)Mains & EUT Connections: HV Coax (Direct); L, N and PE via CouplerPhase synchronization: Asynchronous/synchronous 0 - 360° ±2°Polarity: Positive/NegativePulse amplitude: 200 Volts - 4.5 kV (20 Volt Steps)Repetition time: 100ms to 10sTest duration: 1 to 150 pulses (15ms burst duration as per IEC 61000-4-4 up to 10 kHz)$975.00In Stock -
Was:$48,000.00$14,400.00In Stock
-
Teseq (Schaffner) NSG 2050 System PNW 2050 w/ CDN 131/133
SKU: sku-1050
Standards Met: IEC/EN 61000-4-5, IEC/ISO 60601-1-2Applications: EMC Surge, CE Marking, Surge ImmunityMax EUT AC Voltage (W/ Built In CDN): 690 VoltsMax EUT AC Current (W/ Built In CDN): 32 AmpsMax EUT DC Voltage (W/ Built In CDN): 270 VoltsMax EUT DC Current (W/ Built In CDN): 16 AmpsCombination/Wave Surge Output Capability: 4.4 kVExternal Coupling: Data Lines (Surge), 3PH EUTWarranty: 100 DaysCondition (5-10 Scale): 8$5,975.001 System Left -
Keytek (Thermo Fisher) CE Master for EFT, Surge, PQF
SKU: sku-583
Immunity Applcations: Surge Immunity (Combo/Ring/Telecom Waves), EFT/Burst, Dips Interrupts & VariationsEMC Standards (Previous Editions): IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11Weight: 29kg (64 lbs)EFT/Burst Output: 500V - 4.4kVSurge Output: 250V - 2.5kVVoltage Drops: 70%, 40%$9,750.001 Unit Available -
Schloder CWG 1500 Surge Generator, 4.4 kV, 2.2 kA, EN/IEC 61000-4-5
SKU: sku-783
Condition (5-10 Scale): 9Warranty: 6 MonthsCalibration: Fresh w/ Data at Time of OrderTest standard: IEC 61000-4-5Accessorries: CompleteInput: 120VAC/1PHPhase synchronization: 0 - 359°, step 1° net sync. triggeringPolarity: pos / neg / alternatePulse current (short circuit): 0.1 - 2.2 kAPulse voltage (open circuit): 0.2 - 4.4 kVTest duration: 10 - 990 sec$7,950.001 LEFT -
Used Haefely PEFT 4010 EFT/Burst Simulator for IEC/EN 61000-4-4
SKU: 101132
Test Capabilities: Electrical Fast Transient ImmunityStandards Met: IEC/EN 61000-4-4Applications: EMC Precompliance TestingMax EUT AC Voltage (w/ Built in CDN): 250 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 110 VoltsMax EUT DC Current (w/ Built in CDN): 16 AmpsEFT/Burst Pulse Output Capability: 5 kVExternal Coupling: Data Lines & 3 Phase EUT$6,500.00In Stock -
EM Test MPG 200 Automotive Micropulse Generator up to 1.1 kV, built in CDN 60V/25A DC
SKU: 11818
Applications: Automotive Electrical Disturbances, EV EMC TestingStandards Met: ISO 7637Max EUT DC Voltage (w/ Built In CDN): 60 VoltsMax EUT DC Current (w/ Built In CDN): 25 AmpsPeak Inrush Current Capability: 50 AmpsPre-Programmed Pulses: ISO 7637-2 (Pulse 1 and 6) "Output=DUT supply +/- Safety laboratory connectors Coupling To the battery +line Decoupling Via diode and battery supply switch DUT supply Max. 60V/25A"Weight: approx. 20kgDimensions: 19"/6HUGeneral Data: Technical DetailsInput: 115/230V +10/-15%ISO PULSE 6 (12V) AS PER ISO 7637-1:1990: Voltage (o.c.) 25V - 400V Rise time 60us +0%/-50% (10 - 90%) Pulse duration 300us ± 10% (10 - 10%) Int. resistor 30ohm ± 10%Output-2: GOST PULSE 1B (24V), ISO PULSE 6 (12V/24V) and moreRepetition rate: 300us ± 10% (10 - 10%)Test Routines: Quick Start, User Defines Routines, Standards Test Routines ServiceTest voltage: Test Voltage up to 1,100V and GOST PULSE 1B (24V), ISO PULSE 6 (12V/24V)Trigger: automatic, manual, externalWas:$30,000.00$5,000.00 -
Noiseken JSS-003 Automotive Transient Surge Simulator
SKU: sku-JSS-003
Test Standards: JASO D 001-94Max Power Capacity: 50 V DC, 10 ARepetition Frequency of surge generation: 1 ~ 999999Repetition cycle of surge generation: 30s ±10%$24,975.00In Stock -
Schaffner BEST EMC Precompliance Conducted Immunity Test System
SKU: sku-347-1
Applications: EMC Precompliance TestingPeak inrush current capability: 500 A PeakPulse amplitude: Adjustable voltage range: 250 V to 4400 V Voltage amplitude into 50 Ohms: 125 V to 2000 V (± 10%) Voltage amplitude into 1000 Ohms: 250 V to 4000 V (± 20%)Pulse current (short circuit): 125 A to 2000 AStandards Met: IEC 61000-4-4, 61000-4-5, 61000-4-11, 61000-4-29Was:$14,500.00$11,900.00In Stock