SKU: sku-218
Weight:
100 kg (220.5 lb)
Application/Test Type:
Automated Surge Testing for EUT up to 63 Amps, 480 VAC; Three phase (5 wire);
Two phase (4 wire);
Single phase (3 wire)
Current Rating:
3 x 63 Amp continuous (peak 3 x 100 Amp for 30 min.)
Dimensions:
570 x 840 x 630mm (22.4 x 33 x 24.8")
Frequency Range:
DC – 65 Hz with no loss, 400 Hz max. with power loss
Mains & EUT Connections:
HV-surge pulse input from generator (Fischer connector);
Connector for EUT supply input (Screw terminals Phoenix);
Connector for EUT supply output (Screw terminals)
Standards Met:
IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
Voltage Rating:
EUT VAC line to line: 30 to 480 VAC rms; EUT VAC line to ground: EUT VAC 30 to 280 VAC rms, (below 30 V synchronisation not guaranteed, asynchronous mode only); EUT VDC: up to 125 VDC – full current range,
up to 225 VDC – up to 7 A