  • Teseq DPA 3000 Biconical Dipole Antenna 800 to 2800 MHz

    SKU: sku-125

    Impedance: 50 Ohms
    Weight: 180 grams
    Antenna Factor (1 Meter): 30 dB/m to 38 dB/m (0.8 GHz to 2.5 GHz)
    Antennas: Dipole Antennas
    Connector: N female
    Dimensions: (L x W x H): 155 mm x 155 mm x 75 mm
    Frequency Range: 800 MHz to 2800 MHz
    Gain: -2.0 dB to +1.5 dB (0.8 GHz to 2.5 GHz)
    Impedance-2: 50 Ω, nominal
    Standards Met: CISPR 13, CISPR 14-1, CISPR 16-1-4, CISPR 16-2-3, CISPR 22, CISPR 32, EN 61000-6-3, EN 61000-6-4
    VSWR: Under 2.5:1 (1.0 GHz to 2.5 GHz)
  • Teseq (Schaffner) KEMZ 801A EM Clamp Conform with IEC/EN 61000-4-6

    SKU: sku-119

    Weight: approx. 7 kg
    Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling
    Clamp factor (CF): Max (0.15 to 400 MHz): 4 dB (50 Ω system) and 13.5 dB (150 Ω system)
    Connector: N-type female
    Dimensions: 647 mm x 130 mm x 105 mm
    Frequency Range: 10 kHz to 1000 MHz
    Impedance: 50 Ohms
    Max. Cable Diameter: 20 mm
    Maximum Continuous Power: 0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 min
    Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326
  • Com-Power CDN-M325E 150 kHz - 230 MHz 3-Line RF Coupling Decoupling Network

    SKU: 4845

    EMC Standard: IEC/EN 61000-4-6
    Application/Test Type: Three conductor power cable
    Associated Equipment: RF Conducted Immunity Test Systems
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)
    Typically In Stock
  • Teseq CDNE M310 Coupling/Decoupling Network for Emission Measurement, 10 A, 30 to 300 MHz

    SKU: sku-87

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range
    Common Mode Impedance: Common mode impedance (EUT port): 150 Ω +10/-20 Ω
    Current Rating: 10 Amps
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 30 MHz to 300 MHz
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 10 Volts
    Standards Met: CISPR 16-2-1 edition 3.0, CISPR 16-2-1, CISPR 15 and IEC 61000-4-6
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: C max. voltage (line to ground): 300 V; AC max. voltage (line to line): 520 V; DC max. voltage: 300 V; Tes Voltage: 2000 V AC, 2 s
  • Teseq CDN M216 1kV CDN for CISPR 16-1-2, CISPR 16-2-1 and CISPR 15

    SKU: sku-86

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range.
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • PMM L3-100 Three Phase 100 Amp LISN for CISPR 16-1-2

    SKU: 10058

    Weight: 70 kg (154 pounds)
    Current Rating: 100 Amps continuous (125 Amps overload for 5 minutes)
    Dimensions: 465 x 450 x 740 mm (18.3 x 17.7 x 29 inches) - mounted on pallet for mobility
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 Ω // [5 Ω + 50 µH] with 250 µH choke
    Mains & EUT Connections: 125 A plug and socket outlet according to IEC309 standard
    RF Connector: BNC (f)
    Standards Met: CISPR 16-1-2, VDE 0876, FCC Part 15, MIL-STD 461F
    Voltage Rating: 230 VAC, 325 VDC (L-PE and N-PE); 400 VAC, 565 VDC (L-L and L-N)
    Inquire for Availability
  • Com-Power CDN-M225E Coupling Decoupling Network for Unscreened Power Supply Lines

    SKU: sku-54

    Weight: 5 lbs. 2.3 kg
    Application/Test Type: two conductor power cable
    Common Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
    Current Rating: 25 Amps AC / 17 Amps DC (Max)
    Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)
    Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: 4 mm shrouded banana sockets
    RF Connector: 50 Ω BNC (Female)
    RF Input Voltage: 40 V (Max)
    Standards Met: IEC / EN 61000-4-6
    Voltage Division Factor: 9.5 dB +4 / -1
    Voltage Rating: 250 V AC / 350 V DC (Line to Ground)