RF Current Probe Calibration Fixtures Test Equipment, Systems & Solutions
-
Tekbox TBBCI1-CAL Bulk Current Calibration Fixture
SKU: 7256
Frequency Range: 150 kHz - 400 MHzApplications: IEC 61000-4-6 , MIL-461 , RF Conducted ImmunityImpedance: 50 ΩIn Stock -
CP-CF Calibration Fixture for Current Probes
SKU: sku-1911
Max Probe Girth: 2.75"Fits Probe Arpetures: 1.25" to 1.75"Frequency Range: 20 Hz - 500 MHzInsertion Loss: < 2dBConnetors: N(f)In stock -
Fischer FCC-BCICF-6-150 Bulk Current Injection Probe Fixtures
SKU: sku-1668
Weight: 2.2kgDimensions: (L x W x H) 432mm x 229mm x 80mmFrequency Range: 150 kHz – 230 MHzInsertion loss: less than 1.6dB -
Fischer FCC-BCICF-2 Bulk Current Injection Probe Fixtures
SKU: sku-1667
Frequency Range: 10 kHz – 1 GHz -
Fischer FCC-BCICF-1 Bulk Current Injection Probe Fixtures
SKU: sku-1666
Weight: 2.5kgDimensions: (L x W x H) 250mm x 177mm x 175mmFrequency Range: 10 kHz – 400 MHzVSWR: Meets DO-160 standalone limit line -
AH Systems CPF-532 Calibration Fixture for Injection & Monitoring Current Probes
SKU: sku-207
Weight: 13 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 12" x 7" x 8"Frequency Range: 10 kHz - 400 MHz -
AH Systems CPF-531 Calibration Fixture for RF Current Probes
SKU: sku-206
Weight: 10 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 10" x 7" x 7"Frequency Range: 1 MHz - 1 GHz -
AH Systems CPF-630 Current Monitoring Probe Calibration Fixture
SKU: sku-205
Weight: 9 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 10" x 7" x 6"Frequency Range: 20 Hz - 500 MHz -
Teseq PCJ 9201B Probe Calibration Jig
SKU: 11132
Weight: 4.5 Kgs (10 lbs)Dimensions: 26.0 cm x 18.1 cm x 15.0 cm (Max Probe Diameter: 11.5 cm; Min Probe Window Diameter: 1.6 cm; Max: 6.7 cm)Frequency Range: DC to 400 MHzImpedance: 50 OhmsRF Connector: N-typeStandards Met: ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and IEC/EN 61000-4-6VSWR: up to 1 MHz ≤ 1.10:1; 10 MHz ≤ 1.14:1; 30 MHz ≤ 1.22:1; 100 MHz ≤ 1.50:1; 200 MHz ≤ 2.00:1; 300 MHz ≤ 2.75:1; 400 MHz ≤ 3.50:1 -
Com-Power FCLCE-1000 Current Probe Calibration Fixture
SKU: 11601
Output resistance: 50 OhmsRF Connector: N-Type -
AH Systems CPF-631 Current Probe Calibration Fixture
SKU: sku-342
Weight: 9 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 10" x 7" x 6"Frequency Range: 400 MHz - 1.5 GHz -
Pearson Model F-3 Calibration Fixture for MIL-STD-461 CS114, CS115, CS116
SKU: 4513
Frequency Range: 10 kHz to 400 MHzInner Conductor Diameter: 0.94 inches, 24 mmTest Standards: MIL-461 CS114, MIL-461 CS115Additional Test Standard: MIL-461 CS116In Stock