LISN-CISPR16-32A Overview
The LISN-CISPR16-32A is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9 kHz to 30MHz, according to the CISPR 16-1-2 standard. The device is designed for testing 3-phase and single phase, ACpowered equipment with supply voltages up to maximum 450V/260V and 32A. Conducted noise can be measured on each phase and on the neutral conductor. The LISN-CISPR16-32A has separate RF outputs for each phase and neutral and consequently can be coupled with the LISN-CISPR to split the emissions in its common mode and differential mode components. The LISN-CISPR16- 32A has no integrated high pass filter at the RF outputs, but comes with an external 9 kHz coaxial high pass instead. The single-phase DUT socket is available in country-specific variants.
Frequency range | 9 kHz to 30 MHz |
Impedance | 50 Ohm (50 µH + 5 Ω) |
Artificial hand | 220 pF + 511 Ω |
Switchable PE | 50 Ω 50 µH |
• 250µH pre-filter | |
• Separate RF outputs for each line and neutral | |
• Air core inductors | |
• Line voltage | max. 540V/260V / 50 – 60 Hz, CAT |
Max. current per line and neutral | 32A @ 23°C each |
3-phase DUT socket | CEE/IEC60309, 3L+N+PE, 32A, female |
Single-phase DUT socket | country specific |
Power connector | CEE/IEC60309, 3L+N+PE, 32A, male |
Measurement connectors | BNC |
• External 9 kHz high pass filter, N-male / N-female | |
Measurement connectors | +5°C … + 40°C; 5% to 80% RH |