ISO 11452-4 Turn Key Solution for Harness Excitation Methods (BCI and TWC)
SKU: 10459
Test Capabilities: RF Conducted ImmunityStandards Met: ISO 11452-4Applications: Automotive Component Disturbance TestingBCI Test Levels (w/ built-in amplifier): 1000mAFrequency Range (w/ built-in amplifier): 9 kHz - 1 GHzTypically In Stock -
ISO 11452-8 Magnetic Field Immunity Test System
SKU: 10463
Frequency Range: 15 Hz to 150 kHz.Normative References: ISO 11452-1, Road vehiclesOptional: Artificial NetworksMagnetic Field Strengths: up to 1,000 A/mInquire for Lead Time -
LISN-CISPR25-200 LISN
SKU: LISN-CISPR25-200
Applications: Conducted Emissions, BCI Testing , Automotive EV EMCTest Standards: CISPR 25, MIL-STD-461, ISO 7637-2Max EUT DC Voltage: 1,000 VoltsMax EUT Current: 200 AmpsMax EUT AC Voltage (60Hz/400Hz): 700V/300VIN STOCK -
LPA2G 290 MHz - 2 GHz LPDA EMC Antenna
SKU: 3493
Antenna Factor (1 Meter): 14 to 32 db/mAntenna Type: Log Periodic AntennasConnector: N-Type, femaleDimensions: 22.6" x 20.1"Frequency Range: 290 MHz - 2 GHzIn Stock -
Materials for EFT/Burst Laboratory Test Setup
SKU: 11245
Floor Ground Plate Dimensions: 9" by 6" (Custom sizes available)Standards Met: IEC 60601-1-2, IEC 61000-4-2Applications: Test Setup for Burst/EFT, EMC Precompliance Immunity TestingTable Dimensions: .8 meters (H)Table Top Ground Plane: 1.6m x .8mIN STOCK -
Inquire for Availability
-
SS6G-75 RF Power Amplifier for Radiated Immunity
SKU: 13797
Frequency: 1 GHz - 6 GHzOutput Power: 75 Watts P1dBGain: 52 ±3 dBMax RF Input Power: 0 dBmAC Input Power: 1PH/120V/950VACIn Stock -
EMIC-20 EM Injection Clamp for IEC/EN 61000-4-6 Immunity Test
SKU: 7851
Standards: EN/IEC 61000-4-6Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): -.5 dB at 100 kHz to -4 dB at 1 GHz (Min -7 dB at 700 MHzConnector: N-type femaleDimensions: 632 mm x 120 mm x 80 mm$595.00 - $8,500.00Typically In Stock -
$1,575.00Inquire for Availability
-
DC40G-10 Coaxial Directional Coupler
SKU: 30087
Frequency Range: 1 GHz to 40 GHzPower: 50 Watts (CW)Coupling: 10 dBInsertion Loss: 2.1 dBFlatness: ± 1.0 dBInquire for Lead Time -
DC40G-30 Directional Coupler 18 GHz to 40 GHz, 30 Watts of Power
SKU: 30088
Frequency Range: 18 GHz to 40 GHzMax. Power: 30 Watts (CW)Coupling: 20 dB (typical), 21 dB (max.)Flatness: 1 dBVSWR: 1 dBTypically in Stock -
GTEM 550V Vertical GTEM
SKU: 30081
Max. EUT Size: 35(L) x 40(W) x 27(H) cm / 13 x 15 x 10 inStandards for Emissions Testing: CISPR 14-1, IEC 61000-6-3, and IEC 61000-6-4Standards Met: IEC 61000-4-20Applications: Radiated Immunity, Radiated EmissionsInquire for Lead Time