Lumiloop LSPM 1.0 3 Channel RF Power Monitor

Condition:
New
Frequency Range:
9 kHz – 6 GHz
Operation:
Up to 12 GHz
Dynamic Range:
90dB
Channels:
1, 2 or 3
Applications:
Radiated Immunity, RF Conducted Immunity
Manufacturer:
Lumiloop
Online Orders Ship Same Day
$795.00
SKU:
7010-RE

 


 

Availability:

In Stock


Lumiloop LSPM 1.0

Standard Accessory Kit:

POWER METER HEAD
TYPE K FEMALE CONNECTOR
FC/ST OPTIC CONNECT
15M EXTENSION CABLE
CABLE KITS/E2000 COUPLERS
INTERFACE CI-250 SN/ 609
ST/FC FO CONNECTS
SOFTWARE/ USB/CAL DATA
USB CABLE
AC ADAPTOR
HARD CASE

The LSPM 1.0 Triple High-Speed Power Meter is a three channel, high speed, high accuracy and high dynamic range RF Power Meter. Single and dual channel versions are available as well. Its frequency range is 9 kHz – 6 GHz. Operation up to 12 GHz is supported with reduced performance.

Compensation of linearity, frequency and an actively controlled power sensor temperature guarantee accurate measurements from less than ‑50dBm to at least 20dBm. A dynamic range of 90dB is achieved for many frequencies.

The LSPM 1.0 High-Speed Power Meter’s high sampling rate allows for high resolution time-domain signal analysis.
The Power Meter can be synchronized with signal generators in order to realize high resolution pulse analysis.

LSPM 1.0 High-Speed Power Meters can be combined seamlessly with LUMILOOP’s LSProbe E‑Field Probes to accelerate standard EMC measurements such as IEC61000‑4–3 and 61000–4‑21 by a factor of more than 100 over traditional setups.
Rearward connectors are available upon request.

[split]

 

LSPM 1.0

LSPM 2.0

Frequency Range
   Low Band 9 kHz ... 400 MHz 9 kHz ... 1 GHz
   High Band 30 MHz ... 6 GHz 700 MHz ... 26.5 GHz
Analog Rise Time
   Low Band 1.0 ms (VBW 460 Hz 1.1 ms (VBW 400 Hz)
   Low Band 800 ns (VBW 510 kHz) 550 ns (VBW 850 kHz)
   High Band 190 ns (VBW 2.0 MHz 20 ns (VBW >50 MHz)
Minimum Pulse Width 500 ns 500 ns
VSWR <1.20:1 <1.22:1 up to 12 GHz
<1.42:1 up to 26.5 GHz
Sampling Rate 2 MSamples/s 2 MSamples/s
Measurement Range & Dynamic Range
   Low Band <-68 dBm ... >20 dBm 0.1 to 100 MHz 
<-50 dBm ... >20 dBm 9 kHz to 400 MHz
<-75 dBm ... >23 dBm up to 100 MHz
<-60 dBm ... >23 dBm up to 1 GHz
   High Band <-60 dBm ... >20 dBm up to 1 GHz
<-50 dBm ... >20 dBm 1 ... 6 GHz
 <-45 dBm ... >12 dBm 1 ... 22 GHz 
<-40 dBm ... >12 dBm 22 ... 26.5 GHz
Amplitude Accuracy* 0.1 dB 0.15 dB
Linearity Error  0.15 dB 0.15 dB
Temperature Stability  0.1 dB  0.1 dB
Power Resolution <0.1 dB
(see plot below)
<0.1 dB
(see plot below)
Channel Isolation >50 dB >60 dB up to 26.5 GHz
Damage Level >30 dBm  >25 dBm
RF Connectors Type N 2.92 mm
Application Software LUMILOOP TCP-Server + GUI, CalImport LUMILOOP TCP-Server + GUI, CalImport
PC Interface  USB 2.0 USB 2.0
Trigger Voltage 5 V 5 V
Trigger Connector  BNC  BNC
Input Voltage 5 V ±5 %  5 V ±5 %
Input Current <3 A <3 A
Ambient Temperature 10 ... 40 °C 10 ... 40 °C
Dimensions (W× D × H) 165 × 142 × 61 mm3 165 × 142 × 61 mm3
Certifications CE CE
*) At 0 dBm, CW, accredited Calibration at esz AG calibration & metrology.

Equipment Specifications