Narda PMM 7010 EMI Test Receiver

Condition:
Used
Manufacturer:
PMM
Frequency Range:
9 kHz to 3 GHz
App Note:
Differences Between EMI Test Receivers and Spectrum Analyzers, Precompliance conducted emissions,
Detectors:
Peak, Quasi-Peak, Average, RMS, RMS-Avg (optional), C-Avg, Smart Detector function
Pre-programmed Test Limits:
CISPR 11, CISPR 22
Sweep/Test Speed:
Slow
Other Features:
Built-in LISN (1PH/16A)
Test Type:
EMC Precompliance Testing, Conducted Emissions, Radiated Emissions
Test Standards:
CISPR 16-1-1, ANSI C63.2, MIL‑STD‑461 and FCC

Downloads

Narda PMM 7010 EMI Test Receiver Datasheet

 

1 review Write a Review
$995.00
Availability:

IN STOCK

SKU:
sku-25-MO

 

Due to tariff increases, some items in our catalog are subject to additional costs when purchased.


Getting Started...

Narda PMM 7010 EMI Test Receiver Overview

The Narda PMM 7010 CISPR 16-1-1 EMI test receiver is an economical, flexible and expandable system for radiated emissions testing. The PMM 7010 has the required RBW filters and detectors specified in CISPR 16-1-1 as a built in 16A, 230VAC line impedance stabilization network (LISN). Using the PES Emission Suite software and a laptop you have the freedom of multitasking, maneuvering equipment and taking your data with you.

The PMM 7010 EMI Receiver is a highly flexible and easy-to-use device suitable for conducted and radiated measurements from 9 kHz up to 3 GHz. Thanks to its built-in 16 A Line Impedance Stabilization Network (LISN), the 7010 performs complete conducted emission measurements and characterization of EUT with no external or additional equipment. The compact, rugged design makes the 7010 a perfect companion for product designers in-site testing, and laboratory EMI measurements.

The innovative PMM 7010 EMI test Receiver combines state-of-the-art digital technology with an RF front-end as required by CISPR standards, thus combining excellent accuracy with high flexibility. The PMM Emission Suite software features a full set of user-friendly functions for all EMI applications.

Included with the Narda PMM 7010 Receiver:

  • PES PMM Emission Suite Software and laptop
  • LISN mains cable
  • RS232 cable
  • USB-RS232 serial converter
  • USB cable
  • N-m to BNC-f adapter
  • AC/DC power adapter
  • soft carrying case
  • user’s manual
  • standard calibration certificate

 

[split]

The receiver can be ordered with four different frequency ranges:

  • 150 kHz to 1 GHz (7010 opt.00)
  • 9 kHz to 1 GHz (7010 opt.01)
  • 9 kHz to 30 MHz (7010 opt.02)
  • 9 kHz to 3 GHz (7010 opt.03)
  • Users can upgrade from one version to another at any time.

Additional Features of the Narda PMM 7010 Receiver:

  • Direct analog to digital conversion up to 30 MHz
  • 140 dBµV (2 W) maximum input level without damage
  • User port for driving external LISN
  • Combination EMI Test Receier and Spectrum Analyzer
  • Robust, compact Construction

 

Built-in LISN (compliant to CISPR 16-1-2):

  • Frequency range: 9 kHz to 30 MHz
  • Continuous rated output current: 16A
  • Max permissible operating voltage: 250 Vac – 350 Vdc
  • EUT supply frequency range: DC to 60 Hz
  • CISPR equivalent circuit: 50 ? // (5 ? + 50 μH)
  • EUT power connector: Schuko 2P+E
  • Artificial hand: 4 mm socket

Videos

Narda PMM 7010 EMI Test Receiver Key Considerations

Manufacturer:
PMM
Frequency Range:
9 kHz to 3 GHz
App Note:
Differences Between EMI Test Receivers and Spectrum Analyzers, Precompliance conducted emissions,
Detectors:
Peak, Quasi-Peak, Average, RMS, RMS-Avg (optional), C-Avg, Smart Detector function
Pre-programmed Test Limits:
CISPR 11, CISPR 22
Sweep/Test Speed:
Slow
Other Features:
Built-in LISN (1PH/16A)
Test Type:
EMC Precompliance Testing, Conducted Emissions, Radiated Emissions
Test Standards:
CISPR 16-1-1, ANSI C63.2, MIL‑STD‑461 and FCC

    1 Reviews

  • Posted by L Nodal on Jun 12, 2025

    4

    Underrated