Haefely EMC Test Equipment, Systems & Solutions
-
Inquire for Availability
-
Haefely PCD 130 3 Phase Coupling/Decoupling Network for PSURGE 8000
SKU: sku-444
Weight: 69 kg (net weight)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: 3 Phase - 32 Amps, 690 VACDimensions: 45 x 50 x 57 cm (W x H x D)General Data: Technical DetailsPhase synchronization: 1° stepsPolarity: pos / negPulse current (short circuit): 32A RMSPulse voltage (open circuit): 690V RMS (Phase-Phase) 110V DCStandards Met: IEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45In Stock -
Rent Haefely PSURGE 4010 Surge Generator for IEC 61000-4-5 Testing
SKU: sku-280
Test Standards: EN/IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2 (IEC 61000-4-9 w/ MSURGE)Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5Pulse current (short circuit): 100 Amps to 2.1 kAPulse repetition: up to 12 per minutePulse voltage (open circuit): 200 Volts to 4.2 kV$895.00 -
Haefely DEC 6 Decoupling Network for Symmetrical Data and Control Lines
SKU: sku-409
Weight: approx. 2 kg netCoupling: Decoupling elements Resistors 200 OhmDimensions: 30 x 20 x 16 cm (w x h x d)DUT current: Current on EUT lines max. 0.1APulse amplitude: max. 6.6kVPulse Shape: 10/700us -5/320us 1.2/50us - 8/20us 100kHz ring waveTest Voltage: Voltage on EUT lines max. 72V DC or 50V AC,RMS (with gas arrestors as protection elements) max. 144V DC or 100V AC,RMS (with ABDs as protection elements)In Stock -
-
Haefely PSURGE 10/700us Telecom Impulse Test System
SKU: sku-248
Polarity: Positive and NegativeTelecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 0.20 – 7.4kV ±10%In Stock -
Haefely PEFT 8010 High Voltage EFT/Burst Generator, 7.3kV
SKU: sku-306
Weight: 14 kgApplication/Test Type: Approval testing, Product development, Post design diagnostics, Industrial, HouseholdBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 1 Hz … 110 kHz (Duration 0.01 - 999 ms)Burst time: 0.1 Hz - 400 Hz; 2.5 ms - 10 s; 1 period - 500 periodsCoupling: Built-in Single Phase AC 264 Volts / 16 Amps 50-60Hz, 10 Amps from 16 - 400 Hz; 125V/10A DC (Modes: L-GND, N-GND, PE-GND, LN-GND, LPEGND, NPE-GND, LNPE-GND)Dimensions: 450mm x 130mm x 570mmGeneral Data: Technical DetailsPolarity: positive / negative / alternatePulse amplitude: 1.0 to 7.3kV (6.6 kV at CDN Output)Repetition time: Impulses per second: max. 250 for Unom over 4 kV; Impulses per burst: max. 500 for Unom 4 kVStandards Met: IEC/EN 61000-4-4 Ed. 1 + 2, IEC 61326, EN 61000-6-1, IEC 61850-3, EN 61000-6-2Supply Voltage: 85 ... 264 VAC, 150 VA, 50 / 60 HzTest duration: 0 s … 8 h per path