Overview
The LISN-CISPR16-63A stabilizes high power, 3 Phase, AC mains and is built in compliance to CISPR 16-1-2. The network can handle AC powered equipment with supply voltages up to maximum 690VAC, 4000VDC and 63 Amps per phase.
Conducted noise can be measured on each phase and on the neutral conductor. 3PH-LISN-ADAP can be used to split the emissions in its common mode and differential mode components.
| Frequency range | 9 kHz to 30 MHz |
| Impedance | 50 Ohm (50 µH + 5 Ω) |
| Artificial hand | 220 pF + 511 Ω |
| Switchable PE | 50 Ω 50 µH |
| • 250µH pre-filter | |
| • Separate RF outputs for each line and neutral | |
| • Air core inductors | |
| • Line voltage | max. 690V/400V / 50 – 60 Hz, CAT |
| Max. current per line and neutral | 32A @ 23°C each |
| 3-phase DUT socket | CEE/IEC60309, 3L+N+PE, 32A, female |
| • External 9 kHz high pass filter, N-male / N-female | |