CISPR Standards

(Showing 12 of 143)

CISPR standards are established, internationally accepted methods to test and comply products against EMC. Manufacturers will find these referenced in their product specific standard, with notes if any adjustments are to be made. The EMC Shop is well versed on CISPR Standards and supports customers to measure and evaluate their product in anticipation of a certificaition test. CISPR is for commercial electronics and automotive vehicles. 

Learn More

The EMC Shop stocks test equipment to test and pre-certify products to CISPR standards.

Show 12 24 36 48 96

CISPR Standards Categories

CISPR Standards Test Equipment, Systems & Solutions

  • Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines

    SKU: sku-230

    Weight: 1.5 kg (3.3 lbs)
    Application/Test Type: Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low current
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 Ω
    Current Rating: 200 mA to 4 Amps (refer to data sheet for exact model specifications)
    Decoupling of Common Mode Disturbance: 10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)
    Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
    Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHz
    Mains & EUT Connections: 4 mm banana or D-Sub 25 pins
    RF Connector: BNC 50 Ω
    RF Input Voltage: 30 Volts Max
    Standards Met: IEC 61000-4-6, CISPR 15
    Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB, 10 dB ±1 dB for CDN A501, A701, A801; 80 MHz to 300 MHz 1): 9.5 dB +3 dB / -2 dB 10 dB +3 dB / -2 dB for CDN A501, A701, A801; All other models 10 dB ±1 dB
    Voltage Rating: AC max. voltage (line to ground): 63V - 160V; DC max. voltage (line to ground): 100V - 250V; Test voltage: 250 V - 400 V DC, 2 sec (refer to data sheet for exact model specifications)
  • Teseq CDN T Series Coupling Network for Unscreened Communication/Data Lines

    SKU: sku-228

    Weight: 0.5 kg (1.1 LB.'s)
    Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMD
    Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω; 80 MHz to (230) 300 MHz: 150 Ω +60 Ω / -60 Ω
    Current Rating: 400 mA (line), 800 mA (pair)
    Decoupling of Common Mode Disturbance: 10 kHz: Over 20 dB; 1.5 MHz / 30 MHz: Over 55 dB; 80 MHz: Over 45 dB; 230 MHz: Over 35 dB;
    Dimensions: 4.1 x 2.5 x 4.3 inches (10.5 cm x 6.5 cm x 11.0 cm)
    Frequency Range: 150 kHz to 80 MHz (Optional 10 kHz - 230/300 MHz)
    Mains & EUT Connections: D-Sub adapter to RJ45 / RJ11 (1 mm banana on certain 10 kHz models)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 9.5 dB ±1 dB (10 kHz to 230 MHz: 10 dB ±1 dB)
    Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s
  • Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps

    SKU: sku-227

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 10 dB +3 dB / -1 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M432 32 Amp Coupling/Dcoupling Network

    SKU: sku-226

    Weight: 6.5 kg (14.3 LB.'s)
    Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 32 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6
    Voltage Division Factor: 10 dB +3 dB / -1 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
    $270.00
  • Teseq CDN M416 4-Line Coupling/Decoupling Network

    SKU: sku-225

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M316 Coupling/Decoupling Network (CDN) CDN M3 Type

    SKU: sku-224

    Weight: 700 grams (1.5 LB.'s)
    Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)
    Common Mode Impedance: 150 Ω +10/-20 Ω
    Current Rating: 10 Amps Maximum
    Decoupling of Common Mode Disturbance: Greater than 30 dB
    Dimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)
    Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
    Insertion Loss: Greater than 0.1 dB
    Mains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)
    RF Connector: BNC, 50 Ω
    RF Input Voltage: Less than 30 V
    Standards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
    Voltage Division Factor: 20 dB ±1.5 dB
    Voltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
  • Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port

    SKU: sku-223

    Weight: 3.3 Lbs (1.5 kg)
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 10 Amps
    Decoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    Frequency Range: 150 kHz to 230 MHz
    Insertion Loss: Less than 0.1 dB
    Mains & EUT Connections: AE Euro: IEC 60320 C14 EUT-socket 2lines: CEE 7/17;
    RF Connector: BNC 50 Ω
    RF Input Voltage: 30 Volts Max
    Standards Met: IEC/EN 61000-4-6
    Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
    Voltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
    $1,020.00 - $1,445.00
  • Teseq DPA 3000 Biconical Dipole Antenna 800 to 2800 MHz

    SKU: sku-125

    Impedance: 50 Ohms
    Weight: 180 grams
    Antenna Factor (1 Meter): 30 dB/m to 38 dB/m (0.8 GHz to 2.5 GHz)
    Antennas: Dipole Antennas
    Connector: N female
    Dimensions: (L x W x H): 155 mm x 155 mm x 75 mm
    Frequency Range: 800 MHz to 2800 MHz
    Gain: -2.0 dB to +1.5 dB (0.8 GHz to 2.5 GHz)
    Impedance-2: 50 Ω, nominal
    Standards Met: CISPR 13, CISPR 14-1, CISPR 16-1-4, CISPR 16-2-3, CISPR 22, CISPR 32, EN 61000-6-3, EN 61000-6-4