Amplifier Research ATS700M11G Log Periodic Antenna
SKU: 4353
Frequency Range: 700 MHz to 10.5 GHzImpedance: 50 Ω nominalVSWR (Typical): <1.5:1 to 7 GHz, ≤2.8:1 7 GHz to 10.5 GHzConnector: N-Type (f)Front to Back Ratio: -15 dB (minimum)Applications: RF Radiated Susceptibility TestingTest Standards: IEC 61000-4-3$1,095.00In Stock -
Steatite QWH-SL-2-18-S-HG-R Linearly Polarised High Gain Wideband Ridged Horn Antenna
SKU: 1058
Frequency: 2 to 18 GHzGain: 9.3 to 22.8 degreesAntenna Factor: 24 to 35 dB/mConnector Type: SMA type jackPower Handling: 20 Watt c.w.Typically In Stock -
Schwarzbeck FMZB 1513 Active Receive Loop Antenna
SKU: 30113
Applications: Antenna Pattern MeasurementTest Standards: CISPR, MIL, FCC Part 15, ISO, ETSIFrequency Range: 9 kHz - 30 MHzConnector: 50 Ω N-Type (f)Frequency Response: < +/- 1 dBLoop Diameter: 0.5 mTypically In Stock -
Teseq (Schaffner) NSG 2050 System PNW 2050 w/ CDN 131/133
SKU: 11050
Standards Met: IEC/EN 61000-4-5, IEC/ISO 60601-1-2Applications: EMC Surge, CE Marking, Surge ImmunityMax EUT AC Voltage (W/ Built In CDN): 690 VoltsMax EUT AC Current (W/ Built In CDN): 32 AmpsMax EUT DC Voltage (W/ Built In CDN): 270 VoltsMax EUT DC Current (W/ Built In CDN): 16 AmpsCombination/Wave Surge Output Capability: 4.4 kVExternal Coupling: Data Lines (Surge), 3PH EUTWarranty: 100 DaysCondition (5-10 Scale): 8Equipment Group: Combination Wave GeneratorsTest Setup: Surge Immunity Test, Setup, Equipment$5,975.001 System Left -
Amplifier Research 50W1000B 1 MHz - 1 GHz RF Power Amplifier
SKU: 10922
Frequency Range: 1 MHz - 1 GHzOutput Power: 50 WFlatness: ±1.0 dB typical, ±1.5 dB maximumGain: 47 dB minimum (at max setting)Imput Impedance: 50 ohms, VSWR 2.0:1 maximumOutput Impedance: 50 ohms nominal$695.00In Stock -
Fischer FCC F-120-6A BCI Injection Test Probe
SKU: 11811
Aperture: 40 mmConnector type: Type-NTest Standards: ISO 11452-4, IEC 61000-4-6 BCI, DO-160 Section 20, MIL-STD-461 CS114Frequency Range: 10 kHz – 400 MHzInput Power: 200 wattsInsertion loss: less than 7dB/700kHz - 200MHzRated Power: 100 CWApplications: EMC BCI Tests, Military EMC TestingInquire for Availability -
Thermo Keytek E510A 10kV Surge Generator
SKU: 10799
Standards Met: ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5Phase synchronization: ±15° with optional coupler/decouplerPulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%Pulse repetition: 1 shot/18 secondsPulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt stepsRepetition time: Adjustable from 300ms to 5s; 1ms resolutionTypically In Stock -
AH Systems TDS-535 Tuned Dipole Set, 25 MHz to 1 GHz, Receive and Transmit
SKU: 10742
Weight: 19 lbs.Antennas: Dipole AntennasApplication/Test Type: precise EMI measurementsConnector: N-type (female)Dimensions: Antenna Case: 28” x 23” x 7”Frequency Range: 25 MHz - 1 GHzGain: Varies with ModelImpedance: 50 ohmInquire for Availability -
Amplifier Research 50T4G18, 50 Watts CW, 4.2–18GHz, (TWT) Microwave Amplifier
SKU: sku-717
Weight: 70 lbs, 32 kgDimensions: 19.8 x 6.5 x 27 in., 50.3 x 16.5 x 68.6 cm.Flatness: ±10 dB maximum, 4.2 - 18 GHzFrequency Range: 4.2–18GHzGain: GAIN (at maximum setting) ......47 dB minimum GAIN ADJUSTMENT (continuous range)......35 dB minimumImpedance: 50 ohmsInput: 99-260 VACOutput: POWER (fundamental), CW, @ OUTPUT CONNECTOR Nominal .60 watts Minimum..50 watts Linear @ 1dB Compression..10 watts minimumRF Connector: Type N femaleRF Input Voltage: 1.0 milliwatt maximum for rated output -
EM Test ACC Capacitive Coupling Clamp for ISO 7637 Automotive Testing
SKU: sku-635
Weight: 11.5 kgApplication/Test Type: Electrical Fast Transients for automotive applicationsCable Diameter: up to 40 mm (1.57 in)Coupling Length: 1 m (39.4 in)Dimensions: 1250 mm x 300 mm x 93 mm, L x W x HRF Connector: High voltage connector,coaxial. GND connection 4 mm plug, bananaStandards Met: ISO 7637Voltage Rating: up to 1.0 kVInquire for availability -
3ctest CCC100 EFT/Burst Coupling Clamp for IEC/EN 61000-4-4
SKU: 10621
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Cable Diameter: up to 40 mm (1.57 in)Coupling Length: 1 m (39.4 in)Dimensions: 1040x140x110mmEFT Coupling Clamps: as per IEC 61000-4-4RF Connector: High voltage connector,coaxial. GND connection 4 mm plug, bananaStandards Met: IEC/EN 61000-4-4Voltage Rating: up to 5.5kv4 to 6 Weeks -
Haefely PSURGE 4010 Combination Wave Generator
SKU: 10574
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5Polarity: positive, negative, alternatingPulse current (short circuit): 100 Amps to 2.1 kAPulse repetition: up to 12 per minutePulse voltage (open circuit): 200 Volts to 4.2 kVStandards Met: IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2Industries: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITApplications: Immunity to Electrical Surges (Test Setup)Typically In Stock