Com-Power LI-220C 9 kHz - 30 MHz LISN for CISPR 16-1-2/ANSI C63.4
SKU: 10878
Weight: 20.5 lbs / 9.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 20 Amperes AC, 14 Amperes DCDimensions: 16.75 x 15.5 x 7.5 inches / 42.5 x 39.3 x 19 cmFrequency Range: 9 KHz - 30 MHzInductors: 250 & 50 microhenry (air-core)Insertion Loss: 6 dB to 1 dBIsolation: 20 dB to 40 dBMains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC$295.00 - $3,965.00Typically In Stock -
Solar 7054-2 EMI Voltage Spike Generator
SKU: 30184
Test Standards: DO-160 SECTION 17, MIL-STD-462Applications: EMI/EMC For Military Aircraft And AviationSpike Amplitude: 10 - 400 VoltsSpike Repetition Rate: 0.8 - 10 Pulses Per SecondSpike Rise Time: 10 microseconds$1,750.00 - $1,950.00IN STOCK -
Fischer Custom Communications F-2031-A-DCN-23mm Decoupling Ferrite Tube for IEC 61000-4-6
SKU: sku-727
Weight: 7.5kGApplication/Test Type: ferrite decoupling clampDimensions: Aperture: 23mm Length: 610mm Height: 134mmFrequency Range: 100kHz - 100MHzStandards Met: IEC/EN 61000-4-6 -
EM Test Automotive Test System for ISO 7637-2
SKU: 10596
ISO Automotive Standards: ISO 7637-2, ISO 16750-2, ISO 11452-8Freestyle Mode Micropulses: Programmable Rise time 1us - 10us in steps of 1us; Pulse duration 50us - 10,000us; Int. resistor 2ohm - 100ohm in steps of 5ohm; 200ohm, 400ohm and 450ohmInput: DUT supply +/- DC voltage from VDS 200N or any other DC supply; Pulse 5, 7 From one LD 200NMicropulse: Micropulse module for test pulses 1, 2A and 6Trigger: automatic, manual, external, battery switchUCS 200N Models: Built-in coupling/decoupling networks: UCS 200N50, 80V/50A, 100A@500ms; UCS 200N100, 80V/100A, 150A@500ms; UCS 200N150, 80V/150A UCS 200N200 80V/200AVerification: As per Annex C of ISO 7637-2:2011 into 50ohm and 1,000ohm loadApplications: EMC Testing on EV Electric Vehicles Batteries & Charging Stations, Automotive Electrical DisturbancesInquire for availability -
Keytek E503 Ring Wave Simulator for ANSI/IEEE C62.4 and UL 864
SKU: 10546
Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.Pulse repetition: 1 shot/9 secondsPulse voltage (open circuit): 200V - 6.6kV ± 10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864Equipment Group: Ring Wave Generators/SimulatorsIN STOCK -
Schaffner CDN 8014 Burst/EFT Coupling Clamp for EN/IEC 61000-4-4
SKU: 10545
Compatible Generators: EFT GeneratorsElectrical Noise/Transient ImmunityStandards Met: IEC/EN 61000-4-4$2,990.00Inquire for Availability -
Noiseken ESS-S3011A & GT-30RA Electrostatic Discharge Simulator System for up to 30kV Testing
SKU: 8250
Weight: Approx. 7.0kg (gun holder excluded) Approx. 7.5kg (gun holder included)Air Discharge Voltage Range: 0.20kV to 30.0kV±5%(30.5kVmax)10.0kV : 0.01kV step 30.0kV : 0.1kV stepStandards Met: IEC 61000-4-2, ISO 10605Battery: AC100V to AC240V 50Hz/60Hz ±10% 75VAContact Discharge Voltage Range: 0.20kV to 30.0kV±5% (30.5kVmax) 10.0kV : 0.01kV step 30.0kV : 0.1kV stepPolarity: positive/negativePre-Programmed IEC Levels: YesResolution: 10 Volt steps up to 10 kV; 100 Volt steps to 30 kVTypically In Stock -
Em Test CWS 500N1.4 RF Conducted Immunity Test System for IEC 61000-4-6
SKU: 11251
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6Applications: Radiated Immunity Debugging, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 40VrmsBCI Test Levels (w/ built-in amplifier): 8VrmsFrequency Range (w/ built-in amplifier): 150 kHz - 230 MHzTypically In Stock -
PMM 3010 EMC RF Signal Generator, 9 kHz to 1 GHz
SKU: 30169
Frequency Range: 9 kHz to 1 GHzFrequency Resolution: 1 kHzFrequency Accuracy: ± 10 ppm @ f > 10 MHzLevel Range: -107 to +10 dBmOutput Impedance: 50 ΩConnector: N-Type (f)Applications: Radiated ImmunityTest Standards: IEC 61000-4-3Typically in Stock -
Com-Power FCLCE-1000 Current Probe Calibration Fixture
SKU: 11601
Output resistance: 50 OhmsRF Connector: N-Type -
EMIC-20 EM Injection Clamp for IEC/EN 61000-4-6 Immunity Test
SKU: 7851
Standards: EN/IEC 61000-4-6Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): -.5 dB at 100 kHz to -4 dB at 1 GHz (Min -7 dB at 700 MHzConnector: N-type femaleDimensions: 632 mm x 120 mm x 80 mmFrequency Range: 10 kHz to 1000 MHzMax. Cable Diameter: 20 mmMaximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 minTest Setup and Overview: RF Conducted Immunity Testing$595.00 - $8,500.00Typically In Stock